Evidence map›Paper›PMID 41519946›Full record

ArticlePediatric research2026

Breath-by-breath lung gas volume detection using GASMAS in a neonatal mannequin.

Jurate Panaviene, Pranav Lanka, Konstantin Grygoryev, Andrea Pacheco, Sanathana Konugolu Venkata Sekar, Vicki Livingstone, Eugene M Dempsey, Stefan Andersson-Engels

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jurate PanavieneINFANT Research Centre, University College Cork, Cork, Ireland. jurate.panaviene@ucc.ie.ORCID http://orcid.org/0000-0003-3479-5158
Pranav LankaIrish Photonic Integration Centre, Tyndall National Institute, University College Cork Lee Maltings, Cork, Ireland.
Konstantin GrygoryevIrish Photonic Integration Centre, Tyndall National Institute, University College Cork Lee Maltings, Cork, Ireland.
Andrea PachecoIrish Photonic Integration Centre, Tyndall National Institute, University College Cork Lee Maltings, Cork, Ireland.
Sanathana Konugolu Venkata SekarIrish Photonic Integration Centre, Tyndall National Institute, University College Cork Lee Maltings, Cork, Ireland.
Vicki LivingstoneINFANT Research Centre, University College Cork, Cork, Ireland.
Eugene M DempseyINFANT Research Centre, University College Cork, Cork, Ireland.
Stefan Andersson-EngelsIrish Photonic Integration Centre, Tyndall National Institute, University College Cork Lee Maltings, Cork, Ireland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Monitoring lung gas volumes of ventilated infants is important. Gas in Scattering Media Absorption Spectroscopy (GASMAS) can estimate gas volume inside tissues by measuring oxygen absorption. We hypothesized that GASMAS can detect different tidal volumes (TV) delivered to mechanically ventilated lungs in a neonatal mannequin model breath-by-breath.

methodsA neonatal mannequin was ventilated with a set range of TVs (2-6 ml), different inspired fractional oxygen (FiO

resultsFor both FiO

conclusionGASMAS detects the difference between inspiration, expiration, and tidal volume gas changes, suggesting a potential clinical application of GASMAS for respiratory monitoring of ventilated neonates. IMPACT: What is the key message of your article? An experimental study demonstrating the feasibility of the GASMAS technique for detecting changes in lung gas volume. What does it add to the existing literature? GASMAS detects the difference between inspiratory and expiratory breath phases, various tidal volumes, oxygen concentration, and respiratory rate. What is the impact? This suggests a potential clinical application of GASMAS for respiratory monitoring of neonates.

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.