Implant‑position reproducibility of wired and wireless intraoral scanners and the effects of Wi‑Fi distance and upload speed: an in vitro study.

Takahiro Murakami, Katsuhiro Asaka, Reo Ikumi, Tatsuro Miyashita, Yasuhito Momose, Yoichi Tanaka, Kotaro Saka, Atsushi Okada

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Takahiro MurakamiClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan. m.19871229@gmail.com.
Katsuhiro AsakaClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Reo IkumiClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Tatsuro MiyashitaClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Yasuhito MomoseClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Yoichi TanakaClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Kotaro SakaClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.
Atsushi OkadaClinical Implant Society of Japan, 1-43-9, Komagome, Toshima-ku, Tokyo, 170-0003, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe impact of wireless communication on intraoral scanning reproducibility remains unclear. This in‑vitro study aimed to compare the implant‑position reproducibility of wireless (Wi‑Fi) and wired intraoral scanners using a mandibular edentulous model with six implants and to evaluate how Wi‑Fi distance and upload speed affect reproducibility in wireless intraoral scanners.

methodsAn edentulous mandibular model with six implants was scanned as the reference dataset using a high-accuracy laboratory scanner. Optical impressions were obtained using three wireless intraoral scanners (designated as Primescan 2, SIRIOS, and TRIOS 5) and one wired intraoral scanner (Primescan). For wireless devices, the scanner–router distance was set at 0.5, 2.0, and 5.0 m. The wired Primescan served as the control. Five scans per condition were acquired and analyzed. Upload speed was measured immediately before scanning at each distance tested. The reference and intraoral scanner datasets were superimposed for three-dimensional analysis. Reproducibility was expressed as the concordance rate, i.e., the percentage of surface area within ± 50 μm of the reference dataset. The association between upload speed and reproducibility was examined. The median and interquartile range were calculated for concordance rates; group differences were tested using the Kruskal–Wallis test with Steel–Dwass post‑hoc comparisons, and within‑device associations between upload speed and concordance were examined by linear regression (two‑sided α = 0.05).

resultsPrimescan 2 showed stable concordance across distances (> 78.8%; p > 0.05) and exceeded Primescan at all distances (63.5%; p < 0.05). SIRIOS (64.6→50.4%) and TRIOS 5 (61.6→29.5%) showed decline with distance; at 0.5 m, both were comparable to Primescan, whereas at 5.0 m, TRIOS 5 < SIRIOS (p < 0.05). Across devices at identical distances, Primescan 2 > SIRIOS/TRIOS 5 (p < 0.05). Upload speed correlated with concordance for SIRIOS (β = 0.0369, R² = 0.725, p < 0.001) and TRIOS 5 (β = 0.0707, R² = 0.567, p = 0.001), but not for Primescan 2 (β = 0.0177, R² = 0.077, p = 0.318).

conclusionsPrimescan 2 showed higher implant‑position reproducibility than wired Primescan at all tested distances and was insensitive to Wi‑Fi distance and upload speed. SIRIOS and TRIOS 5 matched the wired comparator at 0.5 m but showed decline at 2.0–5.0 m; upload speed correlated positively with reproducibility for SIRIOS and TRIOS 5, but not for Primescan 2, indicating dependence on device architecture and Wi‑Fi link quality.

Indexed as

Dental ImplantsWireless TechnologyDental Impression TechniqueHumansImaging, Three-DimensionalIn Vitro TechniquesReproducibility of ResultsDental ImplantsCommunicationDental implantsDigital imagingReproducibilityScannerWireless

Identifiers

PMID41519769
PMCPMC12882575

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.