Evidence map›Paper›PMID 41517865›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

Reconfigurable Acoustofluidic Microvortices for Selective Microcargo Delivery.

Lei Wang, Yiqiang Wu, Yiyang Tang, Hui Wei, Tianshi Lyu, Xin Zhang, Tian-Yun Huang

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lei WangLaboratory for Micromachine Intelligence, School of Advanced Manufacturing and Robotics, PKU Research Center for Robotics, Peking University, Beijing, China.
Yiqiang WuLaboratory for Micromachine Intelligence, School of Advanced Manufacturing and Robotics, PKU Research Center for Robotics, Peking University, Beijing, China.
Yiyang TangLaboratory for Micromachine Intelligence, School of Advanced Manufacturing and Robotics, PKU Research Center for Robotics, Peking University, Beijing, China.
Hui WeiLaboratory for Micromachine Intelligence, School of Advanced Manufacturing and Robotics, PKU Research Center for Robotics, Peking University, Beijing, China.
Tianshi LyuDepartment of interventional and vascular surgery, Peking University First Hospital, Beijing, China.
Xin ZhangDepartment of Sports Medicine, Peking University Third Hospital, Institute of Sports Medicine of Peking University, Beijing, China.
Tian-Yun HuangLaboratory for Micromachine Intelligence, School of Advanced Manufacturing and Robotics, PKU Research Center for Robotics, Peking University, Beijing, China.ORCID https://orcid.org/0000-0002-1148-1669

Funding

Beijing Municipal Natural Science Foundation 7232140Clinical Medicine Plus X-Young Scholars Project (Peking University, Fundamental Research Funds for the Central Universities)Interdisciplinary Research Program of Peking University First Hospital 2023IR05National Natural Science Foundation of China 12502123National Natural Science Foundation of China 12588301National Natural Science Foundation of China U25B20129Peking University Third Hospital Fund for Interdisciplinary Researchthe National Key Research and Development Program of China 2023YFB3507003the Peking Nanofab
6 · The paper itself

Abstract

Microscale cargo delivery systems improve precise therapies by enabling delivery of microscale payloads deep into anatomical cavities through complex microvascular networks. Traditional methods face challenges, such as slow infusion, low payload throughput, and poor selectivity at microchannel bifurcations. Inspired by rotifers' adaptive predation, we introduce reconfigurable microvortex generators (r-MVGs) featuring a frequency-encoded acoustofluidic actuation mechanism, which can dynamically switch multiple modes under a single tunable ultrasound field. Diverging from conventional single-mode microvortex or magnetic systems, the present approach leverages pairwise microbubble resonance encoding. This mechanism, wherein microbubbles of discrete sizes resonate at distinct acoustic frequencies, enables controlled attraction-repulsion transitions and programmable microvortex reconfiguration. These acoustically driven micromachines include a programmable active component and a passive nozzle connected by a rotary hinge controlled by paired microbubbles, creating directed microvortices. Simulations and experiments show that each bubble pair defines a unique frequency band, enabling multiple, independently tunable reconfigurable modes and real-time switching between capture, release, and directional delivery. Using this platform, we successfully achieved selective payload guidance through a trifurcated microchannel network via active flow control. This frequency-encoded r-MVG system thus establishes a new paradigm for adaptive, multimodal, and high-throughput acoustofluidic delivery in microfluidics, biomedicine, advanced manufacturing, and nano-reservoir exploration.

Indexed as

AcousticsDrug Delivery SystemsMicrobubblesMicrofluidicsAnimalsEquipment Designintelligent micromachinesmulti‐modal switchingreconfigurable microvorticesselective delivery

Identifiers

PMID41517865
PMCPMC13042385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.