ArticleSensors (Basel, Switzerland)2026
Adaptive Thermal Imaging Signal Analysis for Real-Time Non-Invasive Respiratory Rate Monitoring.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Nostril-Anchored Geometric ROI Projection for Contactless Forehead Skin Temperature Estimation Using Low-Resolution Thermal Imaging.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
(1) Background: This study presents an adaptive, contactless, and privacy-preserving respiratory-rate monitoring system based on thermal imaging, designed for real-time operation on embedded edge hardware. The system continuously processes temperature data from a compact thermal camera without external computation, enabling practical deployment for home or clinical vital-sign monitoring. (2) Methods: Thermal frames are captured using a 256×192 TOPDON TC001 camera and processed entirely on an NVIDIA Jetson Orin Nano. A YOLO-based detector localizes the nostril region in every even frame (stride = 2) to reduce the computation load, while a Kalman filter predicts the ROI position on skipped frames to maintain spatial continuity and suppress motion jitter. From the stabilized ROI, a temperature-based breathing signal is extracted and analyzed through an adaptive median-MAD hysteresis algorithm that dynamically adjusts to signal amplitude and noise variations for breathing phase detection. Respiratory rate (RR) is computed from inter-breath intervals (IBI) validated within physiological constraints. (3) Results: Ten healthy subjects participated in six experimental conditions including resting, paced breathing, speech, off-axis yaw, posture (supine), and distance variations up to 2.0 m. Across these conditions, the system attained a MAE of 0.57±0.36 BPM and an RMSE of 0.64±0.42 BPM, demonstrating stable accuracy under motion and thermal drift. Compared with peak-based and FFT spectral baselines, the proposed method reduced errors by a large margin across all conditions. (4) Conclusions: The findings confirm that accurate and robust respiratory-rate estimation can be achieved using a low-resolution thermal sensor running entirely on an embedded edge device. The combination of YOLO-based nostril detector, Kalman ROI prediction, and adaptive MAD-hysteresis phase that self-adjusts to signal variability provides a compact, efficient, and privacy-preserving solution for non-invasive vital-sign monitoring in real-world environments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.