ArticleSensors (Basel, Switzerland)2025
In Situ Calibration Method for an MGT Detection System Based on Helmholtz Coils.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Vector magnetometer arrays are essential for ferromagnetic target detection and MGT measurement, but their performance is limited by proportional factor errors, triaxial non-orthogonality, soft/hard iron interference, and inconsistent array orientations. Traditional rotation-based scalar calibration requires magnetic-free turntables or manual multi-orientation operations, introducing mechanical noise, orientation perturbations, and poor repeatability. This paper proposes an in situ rapid calibration method for MGT systems using triaxial Helmholtz coils. By generating three-dimensional magnetic field sequences of constant magnitude and random directions while keeping the sensors stationary, the method replaces conventional rotational excitation. A two-stage rapid calibration algorithm is developed to achieve individual sensor error modeling and array relative calibration. Experimental results show substantial improvements. The tensor invariant C
Indexed as
Identifiers
What OpenQuestion holds
Registered trials