Evidence map›Paper›PMID 41516537›Full record

ArticleSensors (Basel, Switzerland)2025

Novel Filter-Based Excitation Method for Pulse Compression in Ultrasonic Sensory Systems.

Álvaro Cortés, María Carmen Pérez-Rubio, Álvaro Hernández

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Álvaro CortésDepartment of Electronics, Polytechnic School, University of Alcalá, 28805 Alcalá de Henares, Madrid, Spain.ORCID 0000-0002-1740-4672
María Carmen Pérez-RubioDepartment of Electronics, Polytechnic School, University of Alcalá, 28805 Alcalá de Henares, Madrid, Spain.ORCID 0000-0001-8271-6843
Álvaro HernándezDepartment of Electronics, Polytechnic School, University of Alcalá, 28805 Alcalá de Henares, Madrid, Spain.ORCID 0000-0001-9308-8133

Funding

Community of Madrid CM/DEMG/2024- 007Spanish Ministry of Science, Innovation and Universities PID2021-122642OB-C41; ref. PID2023-151295OB-I00; ref. PID2023-146254OB-C43
6 · The paper itself

Abstract

Location-based services (LBSs) and positioning systems have spread worldwide due to the emergence of Internet of Things (IoT) and other application domains that require real-time estimation of the position of a person, tag, or asset in general in order to provide users with services and apps with added value. Whereas Global Navigation Satellite Systems (GNSSs) are well-established solutions outdoors, positioning is still an open challenge indoors, where different sensory technologies may be considered for that purpose, such as radio frequency, infrared, or ultrasounds, among others. With regard to ultrasonic systems, previous works have already developed indoor positioning systems capable of achieving accuracies in the range of centimeters but limited to a few square meters of coverage and severely affected by the Doppler effect coming from moving targets, which significantly degrades the overall positioning performance. Furthermore, the actual bandwidth available in commercial transducers often constrains the ultrasonic transmission, thus reducing the position accuracy as well. In this context, this work proposes a novel excitation and processing method for an ultrasonic positioning system, which significantly improves the transmission capabilities between an emitter and a receiver. The proposal employs a superheterodyne approach, enabling simultaneous transmission and reception of signals across multiple channels. It also adapts the bandwidths and central frequencies of the transmitted signals to the specific bandwidth characteristics of available transducers, thus optimizing the system performance. Binary spread spectrum sequences are utilized within a multicarrier modulation framework to ensure robust signal transmission. The ultrasonic signals received are then processed using filter banks and matched filtering techniques to determine the Time Differences of Arrival (TDoA) for every transmission, which are subsequently used to estimate the target position. The proposal has been modeled and successfully validated using a digital twin. Furthermore, experimental tests on the prototype have also been conducted to evaluate the system's performance in real scenarios, comparing it against classical approaches in terms of ranging distance, signal-to-noise ratio (SNR), or multipath effects. Experimental validation demonstrates that the proposed narrowband scheme reliably operates at distances up to 40 m, compared to the 34 m limit of conventional wideband approaches. Ranging errors remain below 3 cm at 40 m, whereas the wideband scheme exhibits errors exceeding 8 cm. Furthermore, simulation results show that the narrowband scheme maintains stable operation at SNR as low as -32 dB, whereas the wideband one only achieves up to -17 dB, highlighting the significant performance advantages of the proposed approach in both experimental and simulated scenarios.

Indexed as

encoding techniquesmulti-carrier modulationultrasonic sensory systems

Identifiers

PMID41516537
PMCPMC12787631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.