ArticleSensors (Basel, Switzerland)2025
A Six-Tap 720 × 488-Pixel Short-Pulse Indirect Time-of-Flight Image Sensor for 100 m Outdoor Measurements.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Long-range, high-resolution distance measurement with high ambient-light tolerance has been achieved using a 720 × 488-resolution short-pulse indirect time-of-flight (SP-iToF) image sensor featuring six-tap, one-drain pixels fabricated by a front-side illumination (FSI) process. The sensor performs 30-phase demodulation through six-tap pixels in each subframe, combined with five range-shifted subframe (SF) readouts. The six-tap demodulation pixel, designed with a lateral drift-field pinned photodiode, demonstrates over 90% demodulation contrast for a 20 ns light-pulse width. High-speed column-parallel 12-bit cyclic ADCs enable all six-tap subframe signals to be read within 4.38 ms. This high-speed subframe readout, together with efficient exposure-time allocation across the five subframes, enables a depth-image frame rate of 10 fps. The multi-phase demodulation in SP-iToF measurements, operating with an extremely small duty ratio of 0.2%, effectively suppresses ambient-light charge accumulation and the associated shot noise in the pixel. As a result, distance measurements up to 100 m under 100 klux illumination are achieved, with depth noise maintained below 1%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.