Evidence map›Paper›PMID 41515827›Full record

ArticleMaterials (Basel, Switzerland)2026

Temperature Variations in a Flexible Thermoelectric Module with an Evaporative Heat Sink.

Monika Jangas, Anna Dąbrowska, Łukasz Starzak, Bartosz Pękosławski, Agata Kmiecik, Marcin Jachowicz, Szymon Ordysiński

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Monika JangasDepartment of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Wierzbowa 48, 90-133 Lodz, Poland.ORCID 0000-0003-3217-1050
Anna DąbrowskaDepartment of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Wierzbowa 48, 90-133 Lodz, Poland.ORCID 0000-0003-4295-3005
Łukasz StarzakDepartment of Microelectronics and Computer Science, Lodz University of Technology, Wólczańska 221 Building B18, 93-005 Lodz, Poland.ORCID 0000-0002-3249-0986
Bartosz PękosławskiDepartment of Microelectronics and Computer Science, Lodz University of Technology, Wólczańska 221 Building B18, 93-005 Lodz, Poland.ORCID 0000-0001-9626-4040
Agata KmiecikDepartment of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Wierzbowa 48, 90-133 Lodz, Poland.ORCID 0009-0000-4455-8995
Marcin JachowiczDepartment of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Wierzbowa 48, 90-133 Lodz, Poland.ORCID 0000-0002-6402-6897
Szymon OrdysińskiDepartment of Safety and Health Management, Central Institute for Labour Protection-National Research Institute, Czerniakowska 16, 00-701 Warsaw, Poland.ORCID 0000-0002-5907-6582

Funding

Ministry of Science III-54
6 · The paper itself

Abstract

Exposure to hot microclimate constitutes a serious threat to human health, especially in environments where collective protection measures cannot be implemented. Despite technological advances, personal cooling solutions remain insufficient for long-term use. Thermoelectric modules (TEMs) offer a promising pathway for developing cooling garments. This paper deals with temperature variations in a cooling set composed of a TEM and an evaporative heat sink, for different supply currents. A special methodology was adopted that included the use of a skin model placed in a climatic chamber, and temperature sensors that allowed temperatures at several points to be recorded. After 30 min of operation, the cold side temperature of the TEM was approximately 3 °C to 4.5 °C lower than when the heat sink was absent and the TEM was not supplied. This is close to what thermal comfort requires and may become too small for longer operation or less favourable climatic conditions. Enhanced heat dissipation from the hot side is therefore essential for enabling TEMs to function effectively in wearable colling systems, which makes research on heat sinks other than evaporative ones necessary.

Indexed as

cooling garmentflexible thermoelectric moduleheat sinkPeltier effectthermoelectric coolingthermoelectric module

Identifiers

PMID41515827
PMCPMC12786848

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.