Evidence map›Paper›PMID 41513950›Full record

ArticleScientific reports2026

Finite element analysis and clinical application of percutaneous sustentaculum tali screw fixation for Sanders type II and III calcaneal fractures.

Hongshi Han, Xian Li, Chengzhi Ha, Chuanwang Huang, Caixia Jin, Jun Yan, Haijuan Liu

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hongshi Han *School of Clinical Medicine, Shandong First Medical University (Shandong Academy of Medical Sciences), Jinan, China.
Xian Li *Department of Orthopaedic Surgery, Beijing Jishuitan Hospital Liaocheng Hospital, Liaocheng, China.
Chengzhi HaDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital Liaocheng Hospital, Liaocheng, China.
Chuanwang HuangDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital Liaocheng Hospital, Liaocheng, China.
Caixia JinDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital Liaocheng Hospital, Liaocheng, China.
Jun YanDepartment of Orthopaedic Surgery, Beijing Jishuitan Hospital Liaocheng Hospital, Liaocheng, China. awpkaka@126.com.
Haijuan LiuDepartment of Endocrinology, Liaocheng People's Hospital, Liaocheng, China. emilyeffi@163.com.

Funding

Natural Science Foundation of Shandong Province ZR2021MH248
6 · The paper itself

Abstract

In calcaneal fractures, percutaneous screw fixation (PSF) is currently considered a promising alternative to established techniques such as the L-shape or sinus tarsi approach. The present study establishes a novel percutaneous sustentaculum tali (ST) screw fixation model for Sanders type II and type III calcaneal fractures, assessing construct stability via finite element analysis (FEA) while concurrently evaluating clinical efficacy through postoperative follow-up. This study utilized FEA, based on the Sanders III fracture line model, to compare the stability of internal implants and fracture fragments between the percutaneous ST screw fixation model, the intramedullary nail model, the locking compression plate (LCP), and minimally invasive plate (MIP), thereby evaluating the biomechanical stability of the percutaneous ST screw construct. In parallel, 23 clinical surgical cases of percutaneous ST screw fixation were included. Through postoperative follow-up, the therapeutic effect was observed to jointly verify the effectiveness of percutaneous ST fixation. Regarding the FEA, after stress loading, among the four internal fixation models, the peak von Mises stress within the calcaneus was maximal in the intramedullary nail model and minimal in the ST screw model. Regarding implant-related stresses, the LCP model exhibited the highest von Mises stress, while the percutaneous ST screw model demonstrated the lowest. In parallel, the maximal fragment displacement in every model was below the reference threshold (150 μm). Percutaneous ST screw fixation demonstrates equivalent biomechanical stability compared with the other constructs. In the clinical follow-up, both the AOFAS and MFS indicated good to excellent functional outcomes, and the low VAS values reflected minimal to no pain, collectively confirming satisfactory restoration of foot function. This study, through FEA and postoperative clinical follow-up, validates percutaneous ST screw fixation as a reliable modality for Sanders type II and III calcaneal fractures, thereby providing an evidence-based reference for calcaneal fracture management. Nevertheless, further biomechanical investigations and larger clinical series are warranted for corroboration.

Indexed as

Bone ScrewsCalcaneusFracture Fixation, InternalFractures, BoneAdultBiomechanical PhenomenaBone PlatesFemaleFinite Element AnalysisHumansMaleMiddle Aged

Identifiers

PMID41513950
PMCPMC12873318

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.