ArticleMikrochimica acta2026
A SERS sensor of Au/Ag nanoparticles grown on the surface of ZnO/PPy@PEDOT: PSS film for detecting norfloxacin residues in milk.
Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
A surface-enhanced Raman scattering (SERS) sensor of Au/Ag nanoparticles (NPs) grown on ZnO/polypyrrole@Poly(3,4-ethylene dioxythiophene)-poly(styrene sulfonate) (PPy@PEDOT:PSS) film for detecting norfloxacin (NFX) residues in milk is presented. The ZnO/PPy@PEDOT:PSS film was prepared by the electrochemical deposition method. Subsequently, Ag NPs and Au NPs were deposited on the surface of ZnO/PPy@PEDOT:PSS film to form a Au/Ag/ZnO/PPy@PEDOT:PSS film by an electrochemical deposition process and the magnetron sputtering process, respectively. Owing to the charge transfer between the SERS substrate and the NFX molecules, this SERS sensor could effectively identify low-concentration NFX molecules with a limit of detection (LOD) of 0.84 nM. Moreover, it could also recognize NFX residues in milk with recoveries of 91.2% to 108.4%. The SERS sensor of Au/Ag/ZnO/PPy@PEDOT:PSS film had a high sensitivity, excellent long-term stability, and significant potential in food safety monitoring applications.
Indexed as
Identifiers
41513929What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.