Evidence map›Paper›PMID 41513904›Full record

ArticleScientific reports2026

In vitro evaluation of different implant systems and their influence on primary stability.

Osmar de Agostinho Neto, João Victor Frazão Câmara, Anton Schestakow, Amanda de Oliveira Pinto Ribeiro, Tamara Teodoro Araujo, Bruno Salles Sotto-Maior

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Osmar de Agostinho NetoFaculty of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
João Victor Frazão CâmaraSaarland University, Homburg, Saar, Germany. jvfrazao92@hotmail.com.
Anton SchestakowSaarland University, Homburg, Saar, Germany.
Amanda de Oliveira Pinto RibeiroFaculty of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
Tamara Teodoro AraujoBauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil.
Bruno Salles Sotto-MaiorFaculty of Dentistry, Federal University of Juiz de Fora, Juiz de Fora, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this in-vitro study was to compare the primary stability and bone quality changes of three milling systems for implants. Osteotomies were performed on fresh, low-density bovine ribs using three different milling techniques for the Strong SW implant system: conventional drilling according to the manufacturer's protocol (control), osseodensification, and bone expander (n = 5 per group). Prior to implant insertion, bone quality at the cervical, body, and apical regions was assessed using micro-computed tomography. Implants were then placed at the bone level, and primary stability was evaluated by measuring insertion torque with a digital torque meter. Bone quality and insertion torque values were statistically analyzed using one-way ANOVA followed by Tukey's multiple comparison test (p = 0.05). There were no statistically significant differences between the cervical, body, and apical regions, as well as among the implant groups SIN, VERSAH, and MAXIMUS (p < 0.05). Furthermore, the insertion torque of the SIN group (35 ± 21.5 N/cm), VERSAH group (43.2 ± 27.1 N/cm), and MAXIMUS group (59.6 ± 28.5 N/cm) also showed no statistically significant differences (p < 0.05). These findings suggest a similarity in bone microarchitecture and insertion strength among the different implants studied. The three milling techniques demonstrated comparable performance, showing no significant differences in bone microarchitecture or primary stability. These results indicate that all systems provided similar conditions for implant insertion in low-density bone.

Indexed as

Dental ImplantsAnimalsCattleOsteotomyRibsTorqueX-Ray MicrotomographyDental ImplantsDental implantMillingOral implantologyTorque controller