Evidence map›Paper›PMID 41512298›Full record

ArticleEuropean journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery2026

Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?

Amila Kahrovic, Harald Herkner, Paul Werner, Philipp Angleitner, Iuliana Coti, Kira Osipenko, Heimo Lagler, Alfred Kocher, Marek Ehrlich, Daniel Zimpfer and 1 more

Abstract read
In one paragraph

Article in European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Amila KahrovicDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0009-0000-1597-720X
Harald HerknerDepartment of Emergency Medicine, Medical University of Vienna, 1090 Vienna, Austria.
Paul WernerDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0003-0925-6160
Philipp AngleitnerDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0002-8378-0633
Iuliana CotiDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0002-1042-9607
Kira OsipenkoDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0009-0007-2166-9933
Heimo LaglerDepartment of Infectious Diseases and Tropical Medicine, Medical University of Vienna, 1090 Vienna, Austria.
Alfred KocherDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0002-2818-2227
Marek EhrlichDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.
Daniel ZimpferDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.ORCID 0000-0002-2185-4895
Martin AndreasDepartment of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, 1090 Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study aimed to assess long-term outcomes of automated titanium fasteners versus hand-tied knots in mitral valve surgery.

methodsIn this retrospective, single-centre analysis, 2678 adult patients who underwent mitral valve repair or replacement between November 2008 and November 2024 at the Medical University of Vienna were included. Patients were grouped according to the suture-securing technique used: automated titanium fasteners versus hand-tied knots. The primary endpoint was prosthetic dehiscence (either mitral annuloplasty ring or valve replacement prosthesis) requiring reintervention. Secondary endpoints comprised ischaemic stroke, intracranial bleeding, and all-cause mortality during the follow-up period.

resultsAmong the study population, 1072 (40%) underwent mitral valve surgery using an automated titanium fastener device, and 1606 (60%) with conventional hand-tied sutures. A total of 31 patients (1.2%) had prosthetic dehiscence during the follow-up period. The risk of prosthetic dehiscence was significantly lower in the automated titanium fastener group in both univariable (crude sub-hazard ratio [sHR] 0.32; 95% confidence interval [CI], 0.12-0.86, P = .023) and multivariable competing risk regression analysis (adjusted sHR 0.34; 95% CI, 0.12-0.91, P = .033). Automated titanium fastener group was not associated with an increased risk of ischaemic stroke (adjusted sHR 0.92; 95% CI, 0.67-1.27, P = .600), intracranial bleeding (adjusted sHR 0.89; 95% CI, 0.52-1.52, P = .675), or all-cause mortality (adjusted hazard ratio 0.93; 95% CI, 0.74-1.18, P = .559).

conclusionsThe use of an automated titanium fastener device seems to be associated with a lower risk of prosthetic dehiscence in mitral valve surgery. Due to the limited number of prosthetic dehiscence events and the potential for residual confounding, the results should be interpreted with caution.

Indexed as

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationMitral ValveMitral Valve AnnuloplastySurgical Wound DehiscenceSuture TechniquesAgedFemaleHumansMaleMiddle AgedRetrospective Studiesautomated titanium fastenerhand-tied knotsmitral valve surgeryprosthetic dehiscence

Identifiers

PMID41512298
PMCPMC12816918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.