Evidence map›Paper›PMID 41512097›Full record

ArticleAnalytical chemistry2026

An Absolute Quantitative Approach to Study the Desorption Step in Plasma-Based Ambient MS Methods.

Odhisea Gazeli, David Moreno-González, Marcos Bouza, Charalambos Anastassiou, George E Georghiou, Antonio Molina-Diaz, Joachim Franzke, Juan F García-Reyes

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Odhisea GazeliAnalytical Chemistry Research Group, Department of Physical and Analytical Chemistry, Universidad de Jaén, Jaén 23071, Spain.ORCID 0000-0003-0352-3213
David Moreno-GonzálezAnalytical Chemistry Research Group, Department of Physical and Analytical Chemistry, Universidad de Jaén, Jaén 23071, Spain.
Marcos BouzaAnalytical Chemistry Research Group, Department of Physical and Analytical Chemistry, Universidad de Jaén, Jaén 23071, Spain.
Charalambos AnastassiouElectromagnetics and Novel Applications Laboratory, Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
George E GeorghiouElectromagnetics and Novel Applications Laboratory, Department of Electrical and Computer Engineering, University of Cyprus, Nicosia 1678, Cyprus.
Antonio Molina-DiazAnalytical Chemistry Research Group, Department of Physical and Analytical Chemistry, Universidad de Jaén, Jaén 23071, Spain.
Joachim FranzkeLeibniz Institut für Analytische Wissenschaften (ISAS e.V), Dortmund 44123, Germany.ORCID 0000-0003-0419-1898
Juan F García-ReyesAnalytical Chemistry Research Group, Department of Physical and Analytical Chemistry, Universidad de Jaén, Jaén 23071, Spain.ORCID 0000-0001-9158-0271

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The desorption step in ambient mass spectrometry, concerted or decoupled with ionization, triggers the transfer of a sample (analytes) from the condensed phase or surface to the gas phase. Depending on the type of method, the desorption is caused by momentum transfer, ultrasound, thermal energy, or laser pulses, among other means. In the case of plasma-based methods, thermally assisted desorption is the most commonly discussed route for analyte desorption, and although often postulated, there is no clear evidence of other mechanisms related to high-energy species created in the discharge. This study addresses the assessment of a protocol to allow absolute quantification of the desorption step during plasma-based ambient MS experiments. As a proof of principle, we measured the desorption efficiency of low-temperature plasma (LTP), which is the more widespread DBD-based ambient MS method. Model analytes such as arginine, cocaine, rhodamine G, or imazalil have been selected to quantify the desorption efficiency using 20 ng in each experiment. Two microliters of analyte solution were deposited on a glass substrate (18 mm × 18 mm) and allowed to dry. Then, they were exposed to different LTP plasma conditions (discharge gas, probe position, and desorption time). After the sample substrate was redissolved with an appropriate solvent, quantitative data were obtained using liquid chromatography/tandem mass spectrometry. Selected experiments have been completed, demonstrating the ability to quantitatively measure the amount of analyte desorbed with high precision (RSD ≤ 7%), finding subtle changes (in the absolute picomole range) when different variables such as discharge gas nature or exposure time were evaluated. Through the use of spatially resolved fluorescence microscopy measurements, we also noticed that analyte deposition is not evenly distributed on the substrate. This evidence, together with the experimental quantitative data, confirms that the conditions used to quantify the desorption are also rugged to experimental aspects such as sample deposition, since the analyte spot size interrogated (1 mm diameter) is distinctly smaller than the LTP probe diameter (4 mm i.d.) and the plasmajet area that impinges the entire sample surface. Analyte-analyte interactions and sample thickness may also be relevant in explaining the desorption in plasma-based ambient MS methods.

Identifiers

PMID41512097
PMCPMC12856827

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked