Evidence map›Paper›PMID 41511626›Full record

ArticleRadiological physics and technology2026

Evaluating the utility of simulated respiratory-gated four-dimensional computed tomography in internal-target-volume-based treatment planning for irregular breathing patterns.

Satoki Hinai, Keisuke Usui, Yusuke Obara, Toshiya Maebayashi, Satoshi Ookubo, Atsushi Ichikawa, Yoshihisa Sasaki, Hajime Sakamoto, Shinsuke Kyogoku, Hiroyuki Daida

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Satoki HinaiDepartment of Central Radiology, Nihon University Itabashi Hospital, 30-1 Oyaguchikami-cho, Itabashi-ku, Tokyo, 173-8610, Japan. hinai.satoki@nihon-u.ac.jp.ORCID http://orcid.org/0009-0001-8905-3453
Keisuke UsuiDepartment of Radiological Technology, Graduate School of Health Science, Juntendo University, Tokyo, Japan.
Yusuke ObaraDepartment of Radiological Technology, Faculty of Medical Technology, Niigata University of Health and Welfare, Niigata, Japan.
Toshiya MaebayashiDepartment of Radiology, Nihon University School of Medicine, Tokyo, Japan.
Satoshi OokuboDepartment of Central Radiology, Nihon University Itabashi Hospital, 30-1 Oyaguchikami-cho, Itabashi-ku, Tokyo, 173-8610, Japan.
Atsushi IchikawaDepartment of Central Radiology, Nihon University Itabashi Hospital, 30-1 Oyaguchikami-cho, Itabashi-ku, Tokyo, 173-8610, Japan.
Yoshihisa SasakiDepartment of Central Radiology, Nihon University Itabashi Hospital, 30-1 Oyaguchikami-cho, Itabashi-ku, Tokyo, 173-8610, Japan.
Hajime SakamotoDepartment of Radiological Technology, Graduate School of Health Science, Juntendo University, Tokyo, Japan.
Shinsuke KyogokuDepartment of Radiological Technology, Graduate School of Health Science, Juntendo University, Tokyo, Japan.
Hiroyuki DaidaDepartment of Radiological Technology, Graduate School of Health Science, Juntendo University, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In internal target volume (ITV)-based treatment planning, respiratory-gated four-dimensional computed tomography (4D-CT) is used to visualize the respiratory motions of lung tumors. However, in cases of irregular breathing, conventional 4D-CT cannot be synchronized with patient-specific respiratory waveforms, which poses challenges to obtaining images that accurately represent the ITV of the tumor. To address this challenge, we propose "simulated respiratory-gated 4D-CT" synchronized with the simulated waveform. This study aimed to assess the precision of ITV delineation using simulated respiratory-gated 4D-CT in patients with irregular breathing. A respiratory motion phantom was employed by inserting a simulated tumor and assessing the method under sinusoidal and irregular breathing conditions. Irregular respiratory waveforms of 20 patients were used to simulate irregular breathing. The phantom was imaged using conventional 4D-CT, slow-scan CT, and our method. For conventional 4D-CT and our method, the average and maximum intensity projections (MIP) were obtained via postprocessing. ITVs corresponding to each respiratory motion were manually contoured. Furthermore, the Dice similarity coefficient (DSC) was computed based on the ITV of conventional 4D-CT. No significant disparity was found between the ITVs obtained using our method and those obtained using conventional 4D-CT under sinusoidal motion. The DSC values of the ITVs derived from our method using MIP were the highest. In the assessment of the irregular respiratory waveforms, the ITVs obtained via MIP using our method closely approximated the ideal ITV in 20 patients. These findings demonstrate that our method can enhance the accuracy of ITV delineation in lung tumors during irregular breathing episodes.

Indexed as

Four-Dimensional Computed TomographyRadiotherapy Planning, Computer-AssistedRespirationRespiratory-Gated Imaging TechniquesHumansLung NeoplasmsPhantoms, ImagingFour-dimensional computed tomographyInternal-target-volume-based planningIrregular breathingRespiratory motion managementSimulated respiratory-gated

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.