ArticleOrthopaedic journal of sports medicine2026

Offloading Patellofemoral Contact Pressures: A Biomechanical Comparison Between Tibial Tubercle Osteotomy and a Retropatellar Tendon Implant.

Erik Haneberg, Andrew Phillips, Tristan Elias, Kevin Credille, Zachary Wang, Elizabeth Shewman, Andrew S Bi, Adam B Yanke

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Erik HanebergDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.
Andrew PhillipsDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.
Tristan EliasDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.
Kevin CredilleDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.
Zachary WangDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.ORCID https://orcid.org/0000-0002-0556-4572
Elizabeth ShewmanDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.
Andrew S BiDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.ORCID https://orcid.org/0000-0002-1703-6232
Adam B YankeDepartment of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA.ORCID https://orcid.org/0000-0002-9601-4217

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A novel retropatellar tendon implant (LIFT) that is fixed deep to the patellar tendon proximal to the tibial tubercle may provide patellofemoral offloading benefits. Purpose/Hypothesis: The purpose of this study was to analyze the patellofemoral contact pressures from 0° to 60° of knee flexion in 3 states: (1) intact knee, (2) knee with the implantation of a retropatellar tendon implant, and (3) knee with a 45° anteromedialization tibial tubercle osteotomy (TTO). It was hypothesized that the implant would significantly reduce the contact pressure between the patella and trochlea compared with the intact state and produce a similar offloading effect as an anteromedializing TTO. Study Design: Controlled laboratory study. Methods: Trochlear pressure sensors were placed in 7 cadaveric knees (6 donors). Patellofemoral contact area, contact pressure, peak force, and center of force were measured using a model for native quadriceps force on the patella. On each specimen, measurements were taken in an intact state, after implantation of a novel retropatellar tendon implant, and after a 45° anteromedializing TTO. Force data were collected from 0° to 60° of flexion in 15° increments and normalized to each specimen's intact state. Results: Compared with the intact and implant groups, the TTO reduced the contact area at 30°, 45°, and 60° of flexion. TTO reduced contact pressure compared with intact from 15° to 60° of flexion, and reduced contact pressure at 15° when compared with the implant. The implant reduced the contact pressure compared with the intact state at 30° and 45° of flexion. For peak force, TTO reduced the force seen in 15° to 60° of flexion compared with the intact condition, while outperforming the implant at 15° of flexion. The implant reduced the peak force compared with the intact condition at 30° of flexion. Center of force analysis revealed that the implant medialized the center of force at 45° and 60° of flexion. Conclusion: The main finding from our biomechanical cadaveric study was that the novel retropatellar tendon implant did not reduce patellofemoral contact area, contact pressure, and peak force as much as a 45° anteromedializing TTO. The implant does reduce peak and contact pressures in early degrees of knee flexion compared with native states. Clinical Relevance: An implant that allows for offloading patellofemoral contact pressures without the morbidity, complication profile, or postoperative rehabilitation associated with a TTO may aid in the treatment of patellofemoral chondral lesions and retropatellar knee pain.

Indexed as

anterior knee painoffloadingpatellofemoralretropatellar tendon implanttibial tubercle osteotomy