ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2026
Automatic measurement and evaluation of anterior segment anatomical structures via UBM images using a deep learning-based approach.
Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
purposeTo develop a deep-learning model capable of measuring essential anterior segment (AS) parameters derived from preoperative ultrasound biomicroscopy (UBM) images of candidates for implantable collamer lens (ICL) surgery.
settingTianjin Medical University Eye Hospital, Tianjin, China.
designCross-sectional retrospective study.
methodsA dataset comprising 1,480 preoperative panoramic UBM images taken from 638 eyes of 320 subjects was collected and was divided into training and testing subsets at a proportion of 7:3. Using the YOLOv8-pose algorithm, the model identified ten anatomical key point coordinates and computed six relevant AS parameters. Both manual and anterior segment optical coherence tomography-based non-contact measurements served as reference standards for evaluating the model's accuracy. The relationship between postoperative vault and preoperative parameters measured by the model was analyzed using multiple linear regression.
resultsOn the test dataset, the model achieved an intraclass correlation coefficient (ICC) exceeding 0.978, with a mean Euclidean distance of 67.65 ± 54.25 μm across all point locations. The ICC values for anterior chamber depth (ACD), pupil diameter, and sulcus-to-sulcus distance were above 0.980 (95% CI: 0.975 to 0.985), with average relative error below 1.7%. Additionally, postoperative vault at one month was significantly correlated with model-measured parameters, including crystalline lens rise, iris concavity, and ACD (P < 0.001).
conclusionThis study introduces a robust program capable of quantitatively measuring AS parameters with accuracy comparable to that of experienced ophthalmologists. The findings provide valuable guidance for ICL sizing and vault prediction.
Indexed as
Identifiers