ArticleScientific reports2026
An improved African vulture optimization algorithm for energy comfort management in occupancy driven smart buildings.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Smart buildings enabled by sensing and control technologies offer opportunities to optimize indoor environmental quality (IEQ) while reducing energy consumption. However, most existing optimization frameworks neglect occupancy dynamics which leads to unnecessary energy consumption and inconsistent comfort. This study proposed a Multi-Trial Vector based African Vulture Optimization Algorithm (MTV-AVOA) with occupancy driven constraint handling mechanism, designed to jointly optimize temperature, humidity, illumination, and air quality. A 528-hour smart office dataset was used to benchmark MTV-AVOA against four state of the art algorithms. The obtained results show that MTV-AVOA delivers average comfort index value during occupied hours is 0.8026. while during non-occupied hours it is 0.750. It also significantly improves from the non-optimized case (0.665) and yields the most balanced overall outcome. The proposed algorithm achieves lower energy consumption during both occupied (638.10 kWh) and non-occupied (528.20 kWh) compared to benchmark algorithms. These evaluation demonstrate that by linking occupancy with IEQ optimization, MTV-AVOA offers an effective balance between comfort and energy efficiency than existing approaches, thus contributing to the development of sustainable smart buildings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.