High-resolution scintillation imaging for detecting delivery errors in preclinical ultrahigh dose rate proton beam therapy.

Megan Clark, Roman Vasyltsiv, David Gladstone, James Kraus, Joseph Harms, Petr Bruza

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Megan ClarkMedical Physics, Radiation Onology, Stanford University, Palo Alto, California, USA.
Roman VasyltsivMedical Physics, Radiation Onology, Stanford University, Palo Alto, California, USA.
David GladstoneMedical Physics, Radiation Onology, Stanford University, Palo Alto, California, USA.
James KrausDepartment of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.
Joseph HarmsDepartment of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.
Petr BruzaMedical Physics, Radiation Onology, Stanford University, Palo Alto, California, USA.

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Fred W Kolling IV · 1985 to 2026
$91.3M
PHASE I FAST TRACK TOPIC 461 CONFORMABLE SCINTILLATOR ARRAY FOR IN VIVO DOSIMETRY DURING RT75N91024C00083 · NCI · DOSEOPTICS, LLC · PI BRUZA, PETR · 2024 to 2025
$2.4M
Training in Surgical InnovationT32EB021966 · NIBIB · DARTMOUTH COLLEGE · PI Eric R Fossum, Sohail K Mirza · 2017 to 2026
$1.7M
NCI NIH HHS 75N91024C00083NCI NIH HHS P30 CA023108NIBIB NIH HHS T32 EB021966NIH HHS NCI 2P30CA023108-46NIH HHS NIBIB T32EB021966Radiation Oncology Institute ROI2023-003
6 · The paper itself

Abstract

backgroundUltrahigh dose rate (UHDR) pencil beam scanning (PBS) proton therapy represents an emerging treatment modality that potentially reduces normal-tissue toxicities, termed the FLASH effect. Despite rapid clinical translation, accurate delivery of dose and dose rate is critical, and current quality assurance and beam monitoring methods have limited capabilities for detecting subtle delivery errors in both spatial and temporal domains. The limitations of existing dosimetry tools make robust characterization and validation of treatment plans during patient-specific quality assurance (PSQA) challenging. PURPOSE: To test a previously validated, high-resolution scintillation imaging dosimetry (SID) system for detecting clinically relevant deviations in proton beam spot position and intensity during UHDR particle beam therapy. The secondary aim of this study was to investigate the impact of spot position and intensity errors on dose rate, emphasizing the need for high spatial and temporal resolution detection systems.

methodsTreatment plans were created for a Varian ProBeam system operating in FLASH mode. Two types of plans were developed, delivered, and imaged: a uniform diamond-shaped and a more complex plan derived from a stereotactic lung treatment protocol. A high-speed (4500 frames per second) imaging system was used to capture temporally and spatially resolved data of light output from a scintillator at isocenter during both types of UHDR PBS deliveries. Image processing was performed in MATLAB, calculating relevant treatment parameters such as cumulative dose, dose per spot, temporal dose deposition throughout the treatment field (dose rate mapping), and dose/dose rate area histograms.

resultsThe imaging system was able to detect deviations in spot position as low as 0.5 ± 0.3 mm and in intensity as low as 7 cGy per spot. Imaging different preclinical treatment fields demonstrated the impact of potential treatment errors on dose rates and dose rate area histograms, with deviations in spot position of 3 mm demonstrating an impact of ± 8% dose rate variations, for example. The spatial and temporal aspects of UHDR PBS deliveries were investigated, highlighting the importance of current high-resolution detectors.

conclusionsHigh-resolution scintillation imaging effectively identifies simulated beam delivery errors in UHDR proton therapy, revealing critical relationships between spatial accuracy and dose rate distribution.

Indexed as

Proton TherapyRadiation DosageScintillation CountingHumansRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-Assisteddosimetryflashproton

Identifiers

PMID41506897
PMCPMC12985973

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.