ArticleLa Radiologia medica2026
A step toward diagnostic reference levels for male varicocele embolization: dosimetric comparison across two generations of angiographic systems.
Article in La Radiologia medica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Greening computed tomography: a position paper on environmentally responsible imaging practice from the computed tomography subspecialty section of the Italian society of radiology.La Radiologia medica · 2026Article
- Human-AI Interaction in Interventional Radiology: A Narrative Review of Current Applications, Challenges, and Future Directions.Journal of imaging · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePercutaneous endovascular embolization (PVE) of male varicocele is a widely adopted procedure performed in healthy young patients with long life expectancy. Dose-optimization systems are therefore essential to minimize procedural radiation risks. We aimed to investigate the effect of a recently implemented dose-reduction technology on dosimetric parameters and its potential implication in the definition of diagnostic reference levels (DRLs). MATERIALS AND
methodsA consecutive series of 113 patients (23.3 ± 9.1 yrs) submitted to PVE between January 2020 and December 2024 were retrospectively reviewed. Two groups based on the angiographic system used, 50 patients treated using the Philips Allura Xper FD20 and 63 patients using the newer Philips Azurion Clarity IQ technology, were compared in terms of demographic, procedural, and dosimetric data.
resultsDespite similar fluoroscopy and procedure times, the recently implemented angiographic technology demonstrated a significant reduction in dose area product (DAP) and reference air kerma (Ka.ref) values (4394.5 vs 20,709 mGy·cm
conclusionThe use of advanced dose-optimization technologies, together with standardized protocols and appropriate operator training, leads to a significant reduction in radiation exposure during PVE, particularly in younger patients. These single-center, retrospective results provide preliminary data that may support the future introduction of procedure-specific DRLs for this routinely and widely performed interventional radiology procedure.