Evidence map›Paper›PMID 41504835›Full record

ArticleMedical & biological engineering & computing2026

A soft hip exoskeleton biomimetic assistance method incorporating dual‑pretension and biomechanics‑based force modeling.

Lei Sun, Wang Lu, Wei Wang, Hao Wang, Minmin Xue, Xinyi Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lei SunThe School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin, 300384, China. sunlei@email.tjut.edu.cn.ORCID http://orcid.org/0009-0002-0684-8478
Wang LuThe School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin, 300384, China.
Wei WangThe School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin, 300384, China.
Hao WangThe School of Electrical Engineering and Automation, Tianjin University of Technology, Tianjin, 300384, China.
Minmin XueThe Health Medicine Department, 983 Hospital of Joint Logistics Support Force, PLA, Tianjin, China.
Xinyi ZhangThe Health Medicine Department, 983 Hospital of Joint Logistics Support Force, PLA, Tianjin, China.

Funding

the China Scholarship Council 202308120058the Key Technologies R&D Program of Tianjin 24YFYSHZ00090the Key Technologies R&D Program of Tianjin 24YFZCSN00030the National Natural Science Foundation of China 62103300
6 · The paper itself

Abstract

Exoskeletons have exhibited increasingly diverse designs and broader applications in rehabilitation and medical fields. To achieve optimal assistance performance, it is essential that the assistive force be synchronized with human biomechanics. However, current soft exoskeletons still face challenges in achieving natural gait synchronization and providing stable, comfortable assistance. This study proposes a biomimetic assistance method for a hip soft exoskeleton that better matches natural human gait. It explores how integrating a dual‑pretension mechanism with biomechanics‑based force modeling can enhance assistive performance, improve user comfort, and reduce metabolic energy consumption during walking. By mimicking the muscle force characteristics of hip joint extension and flexion, two sets of assistive torque curves were developed to correspond with human biomechanical motion. Additionally, to compensate for the hysteresis inherent in the exoskeleton system, a pre‑tension force was applied before and after the assistive curves to improve response time. To enhance the accuracy of gait cycle prediction and achieve better synchronization with natural gait patterns, a Gaussian-weighted moving average algorithm was employed to adaptively assign higher weights to recent gait data, thereby improving the responsiveness and adaptability of the exoskeleton. In the experiments, six subjects participated, and their net metabolic rates were compared under assisted and unassisted conditions. The results showed that the subjects' average metabolic cost decreased by 16.4% at a walking speed of 3 km/h and by 14.1% on a 4° slope. Compared with previous approaches, the proposed algorithm achieved more accurate gait‑phase adaptation and reduced metabolic expenditure, highlighting its potential for human-exoskeleton co‑adaptation.

Indexed as

BiomimeticsExoskeleton DeviceHipHip JointModels, BiologicalAdultAlgorithmsBiomechanical PhenomenaGaitHumansMaleWalkingAssistive forceExoskeletonGait cycleHuman biomechanics

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.