SynthesisInvestigative radiology2026
Rationales for Non-standard GBCA Dosing-Low?-High?-When? and Why?: A Literature-based Study.
Synthesis in Investigative radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Gadopiclenol Breast MRI With Half Standard Gadolinium Dose Maintains High Parenchymal Contrast in Intraindividual Comparison.Investigative radiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe current standard dose of extracellular, multipurpose gadolinium-based contrast agents (GBCAs) of 0.1 mmol Gd/kg body weight (bw) was first suggested in 1984, 40 years ago. Although the safety and efficacy of both higher and lower doses ("non-standard dosing") have been extensively investigated over the years, the recent introduction of high-relaxivity macrocyclic GBCAs provides, for the first time, a viable lower-dose alternative.
objectiveTo systematically explore published rationales for nonstandard dosing of GBCAs and discuss the potential future impact of high-relaxivity contrast agents. MATERIALS AND
methodsA systematic literature review was conducted using Embase and MEDLINE/PubMED, covering studies published from 1991 to 2024. Publications were categorized by clinical indication, administered GBCA dose, study design, and rationale for nonstandard dosing. The dose of 0.1 mmol Gd/kg body weight was defined as the "standard" reference for comparison.
resultsEighty-seven publications comparing different nonstandard dosing regimens with the standard dose were finally selected, which included 43 high-dose and 58 low-dose studies. The rationales for using high-dose administration were to achieve better contrast (25/43; 58%) and to improve lesion detection (15/43; 35%). These high-dose studies were performed primarily in the CNS until 2006. Twenty-nine studies (29/43; 67%) reported improved outcomes compared with standard dose, and 1 study (1/43; 2%) reported comparable outcomes. Rationales for using low-dose administration were related to (1) NSF (31/58; 53%); (2) Gd exposure (23/58; 40%); (3) cost (22/58; 38%); (4) unspecified safety (22/58; 38%); (5) Gd retention/presence (19/58; 33%); and (6) the environment (7/58; 12%). From 1991 to 2006, cost was the primary rationale for lower dose administration. From 2008, NSF was noted, from 2017 onward, Gd retention/presence emerged as an identified rationale, and most recently, to minimize environmental impact. Forty-nine of 58 (84%) investigating low-dose regimens reported comparable outcomes, 7 studies (12%) reported inferior outcomes compared with standard dose. However, 36 of the 49 low-dose studies reporting comparable outcomes modified not only the dose but additionally other parameters, or they applied a study design potentially impacting study strength. To reliably allow for a substantially lower dose across a broad range of indications, the next generation of high-relaxivity low-dose GBCAs (gadopiclenol, gadoquatrane) was developed.
conclusionsFor over 34 years, there has been a consistent demand to lower GBCA doses, with an increasing number of rationales over time. The high-relaxivity, low-dose mGBCAs show promise for reducing Gd dose while maintaining high image quality, potentially defining a new standard dose.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.