Evidence map›Paper›PMID 41503146›Full record

ArticleDEN open2026

Simultaneous Placement of Three Thin-Delivery Multi-Hole Self-Expandable Metallic Stents for Malignant Hilar Biliary Obstruction Using a Large-Channel Duodenoscope.

Akinobu Koiwai, Morihisa Hirota, Tomohiro Oikawa, Kei Ishikawa, Chihiro Yunomura, Takuro Nakaya, Takehito Itoh, Yuki Miyashita, Nana Inomata, Kennichi Satoh

Abstract read
In one paragraph

Article in DEN open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Akinobu KoiwaiDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.ORCID https://orcid.org/0000-0002-7657-1913
Morihisa HirotaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.ORCID https://orcid.org/0000-0001-5682-0911
Tomohiro OikawaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Kei IshikawaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Chihiro YunomuraDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Takuro NakayaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Takehito ItohDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Yuki MiyashitaDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Nana InomataDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.
Kennichi SatohDivision of Gastroenterology Tohoku Medical and Pharmaceutical University Miyagi Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Endoscopic biliary drainage for malignant hilar biliary obstruction is technically demanding especially when multiple ducts require drainage. Plastic inside stents are widely used because of their removability and ease of exchange, but multiple insertion is often hindered by stent interference. Recently, a multi-hole self-expandable metallic stent (MHSEMS) with a thin 5.9-Fr delivery system and side-hole design has been developed to facilitate multi-duct drainage while maintaining communication between biliary branches. An 86-year-old woman presented with fever and vomiting. Laboratory data showed severe inflammation and mild cholestasis. Non-contrast computed tomography and magnetic resonance cholangiopancreatography revealed Bismuth IV hilar obstruction. Emergency endoscopic retrograde cholangiopancreatography achieved drainage by placing two 5-Fr double-pigtail plastic stents into the right anterior and left ducts. After improvement, reintervention was performed using a new duodenoscope (ED-840T; FUJIFILM, Tokyo, Japan) with a 4.5-mm working channel. Cholangiography confirmed dilatation of three hepatic ducts. Three MHSEMSs were inserted simultaneously through their thin 5.9-Fr delivery systems and deployed under fluoroscopic guidance. All stents expanded adequately, achieving effective drainage. This approach may represent an alternative to multi-inside-stent placement, overcoming the technical limitations of stent interference.

Indexed as

biliary drainageduodenoscopeERCPself‐expandable metal stentside‐by‐side

Identifiers

PMID41503146
PMCPMC12772437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.