ArticleScientific reports2026
Reinforcement learning driven adaptive active frequency drift for fast and reliable islanding detection.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Islanding detection remains a critical challenge in grid-connected photovoltaic (PV) systems, as failure to detect islanding conditions can compromise power quality, safety, and system stability. Existing active frequency drift (AFD) methods suffer from two major unresolved limitations: a large non-detection zone (NDZ) and fixed perturbation parameters that cannot adapt to changing grid and load conditions. Despite extensive studies on AFD, no existing method adaptively adjusts its perturbation parameters in response to grid dynamics, creating a significant research gap. To address this specific gap, this work introduces a novel AI-driven adaptive AFD method that uses reinforcement learning to dynamically optimize perturbation behavior to eliminate the NDZ and enhance stability. The proposed method employs Reinforcement Learning (RL) to optimize the chopping fraction (Cf) and an enhanced correction factor (Cr'), which is updated based on the rate of change of frequency (df/dt) and Cf to minimize NDZ while maintaining grid stability. The RL agent is trained using a reward-based learning strategy to achieve fast, accurate islanding detection while minimizing unnecessary disturbances. Simulation and experimental results show that the proposed adaptive AFD achieves islanding detection within 0.12-0.17 s (compared with 0.2-0.5 s for standard AFD) and reduces the NDZ to below 1% (compared with 10-15% for conventional AFD), while keeping total harmonic distortion (THD) within ≤ 2%. These quantified improvements demonstrate substantial gains in detection speed, robustness, and power quality. Experimental validation across different PV configurations confirms the scalability and reliability of the method. The proposed technique, therefore, offers a promising solution for modern smart grids by ensuring compliance with IEEE Std. 929 islanding detection requirements while maintaining high power quality and system stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.