Evidence map›Paper›PMID 41499004›Full record

ArticleCVIR endovascular2026

Embolization of a wide-necked aneurysm of the renal artery ostium using an Amplatzer vascular plug 2: a case report.

Mario Ghosn, Haytham Derbel, Youssef Zaarour, Félix Wei, Vania Tacher, Hicham Kobeiter

Abstract read
In one paragraph

Article in CVIR endovascular, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mario GhosnDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France. ghosn.mario1@gmail.com.ORCID http://orcid.org/0000-0003-3308-3626
Haytham DerbelDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France.
Youssef ZaarourDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France.
Félix WeiDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France.
Vania TacherDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France.
Hicham KobeiterDepartment of Radiology, Henri Mondor Hospital, Assistance Publique - Hôpitaux de Paris (AP-HP), Créteil, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis report describes an embolization technique using a steerable sheath and an Amplatzer vascular plug 2 (AVP 2) to treat a wide-necked aneurysm located at the ostium of the renal artery. Given this particular location, directly attached to the aortic wall, similar to a saccular aneurysm of the abdominal aorta, stent placement or embolization using coils or liquid agents was not feasible. CASE PRESENTATION: A 45-year-old patient with a long medical history including heterozygous SC sickle cell disease, systemic lupus erythematosus, and a left iliac fossa kidney transplant presented with a partially thrombosed right renal artery aneurysm of 45-mm diameter. The aneurysm was located at the ostium of the renal artery that was occluded downstream. The aneurysm was directly attached to the aortic wall with a wide neck measured at 8 mm. Use of coils or liquid agents was not possible because of a very high risk of extra-target embolization. Lack of a patent right renal artery downstream precluded placement of a covered stent. Following multidisciplinary discussion, and due to the patient's high risk for aortic abdominal surgery, endovascular management with embolization was decided. Embolization was performed under local anesthesia, using fluoroscopic guidance and a cone-beam computed tomography three-dimensional road map. Following common right femoral artery access, a 7F steerable sheath was used to catheterize the aneurysm. An AVP 2 was then passed through the sheath in the aneurysm. Particular attention was paid to deploying the last disc of the AVP 2 in the aortic lumen to ensure closure of the aneurysm neck. Final aortic angiogram confirmed exclusion of the aneurysm. There were no intraoperative or postoperative complications. At computed tomography performed 7 months later, the AVP 2 remained in position, and the aneurysm was excluded and partially decreased in size.

conclusionsIn an anatomical presentation that was not a candidate for stent placement or classic embolization techniques, deployment of an AVP 2 using a steerable sheath successfully excluded the aneurysm. This procedure, performed under local anesthesia, obviated the need for abdominal aortic surgical repair or for an aortic stent graft.

Indexed as

Abdominal aortaEmbolizationEndovascularRenal aneurysmVascular plug

Identifiers

PMID41499004
PMCPMC12779785

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.