Evidence map›Paper›PMID 41498850›Full record

ArticleAnalytical chemistry2026

Electrochemical Detection of Organophosphates Using Dual-Modal Enzyme-Based Biosensors.

Zachary T Johnson, Scott A Trammell, Joyce C Breger, Jeffrey S Erickson, Meghna Thakur, Igor L Medintz, David A Stenger

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zachary T JohnsonCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.ORCID 0009-0002-3140-3024
Scott A TrammellCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.ORCID 0000-0002-7996-590X
Joyce C BregerCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.
Jeffrey S EricksonCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.ORCID 0000-0002-0462-9872
Meghna ThakurCollege of Science, George Mason University, Fairfax, Virginia 22030, United States of America.
Igor L MedintzCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.ORCID 0000-0002-8902-4687
David A StengerCenter for Bio/Molecular Science and Engineering Code 6900, U.S. Naval Research Laboratory, Washington, District of Columbia 20375, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Exposure to organophosphates poses a threat to aquatic ecosystems and the public due to their acute toxicity. The dangers caused by organophosphates motivate the development of technologies for prompt detection. Therefore, engineering a portable and compact device that can monitor organophosphate vapors is vital. Electrochemical biosensors present a unique solution for rapid and selective detection of organophosphates, as these sensors are small and sense in real-time. Herein, this study investigates a dual-modal electrochemical system for the detection of dimethyl methylphosphonate (DMMP), a model organophosphate. The enzymes phosphotriesterase (PTE) and acetylcholinesterase (AChE) were chosen for detecting DMMP vapors, as these enzymes chemically engage with the target substrate and produce electrochemically measurable signals. These reaction-specific signals can be read using open circuit potentiometry and amperometry, which produce a turn-on/turn-off signal readout. The turn-on/turn-off signal readout demonstrates the dual-modal mechanism and serves as a complementary verification, thus circumventing the propensity for false positives typically associated with AChE-functionalized biosensors. Deep eutectic solvent films (∼20 μL) compatible with each enzyme were developed to achieve a truly field-deployable device that does not dry out during operation. The PTE- and AChE-modified biosensors yielded detection limits of 17.6 ± 8.7 and 2.5 ± 0.6 ppm, respectively. The dual-sensing device was further validated against a broader range of organophosphates, demonstrating the device's utility as a functional organophosphate sensor. A dual-modal biosensing system presents a unique approach for organophosphate vapor mapping, which results in proper agricultural stewardship.

Indexed as

AcetylcholinesteraseBiosensing TechniquesElectrochemical TechniquesOrganophosphatesOrganophosphorus CompoundsPhosphoric Triester HydrolasesEnzymes, ImmobilizedAcetylcholinesterasedimethyl methylphosphonateEnzymes, ImmobilizedOrganophosphatesOrganophosphorus CompoundsPhosphoric Triester Hydrolases

Identifiers

PMID41498850
PMCPMC12824989

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked