Evidence map›Paper›PMID 41497946›Full record

ArticleCureus2025

Shear Bond Strength of Artificial Teeth to Conventional and Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) Denture Bases: An In Vitro Comparison.

Subhra Rout, Reena Mittal, Ravi Madan, Vinay Rana, Prachi Madan, Mouli Sardar, Krithika J, Meenakshi Tyagi, Seema Gupta

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Subhra RoutDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Reena MittalDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Ravi MadanDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Vinay RanaDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Prachi MadanDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Mouli SardarDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Krithika JDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Meenakshi TyagiDepartment of Prosthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Seema GuptaDepartment of Orthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionComplete dentures remain essential for restoring function and aesthetics in edentulous patients; however, tooth debonding continues to be a leading cause of repair. This in vitro study aimed to compare the shear bond strengths of three types of artificial teeth (crosslinked acrylic, composite, and computer-aided design/computer-aided manufacturing as CAD/CAM-milled teeth) bonded to conventional heat-cured polymethyl methacrylate (PMMA) and CAD/CAM-milled denture base resins. MATERIALS AND

methodsSixty cylindrical specimens (20 mm in height × 25 mm in diameter) were divided into two main groups (n = 30 each) based on the denture base material: conventional heat-cured PMMA and CAD/CAM-milled PMMA. Each group was subdivided (n = 10) according to tooth type: crosslinked acrylic, composite, and CAD/CAM-milled teeth. Teeth were bonded following the manufacturer's protocols for the CAD/CAM group and the standard packing technique for the heat-cured group. The shear bond strength was measured using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed using one-way and two-way analyses of variance with post-hoc tests (p < 0.05).

resultsMean shear bond strength values were as follows: conventional heat-cured base with composite teeth (272.11 ± 85.44 MPa), acrylic teeth (179.09 ± 74.71 MPa), and CAD/CAM-milled teeth (174.47 ± 43.13 MPa); CAD/CAM-milled denture base with CAD/CAM-milled teeth (359.56 ± 76.62 MPa), acrylic teeth (275.51 ± 89.69 MPa), and composite teeth (237.23 ± 75.71 MPa). Two-way analysis of variance revealed significant main effects for both denture base material and tooth type, with a highly significant interaction effect (p < 0.001, η²p = 0.28). The strongest bond was achieved with CAD/CAM-milled teeth on CAD/CAM-milled denture bases, which was significantly higher than that of all other combinations.

conclusionBond strength is highly dependent on material compatibility. The combination of CAD/CAM-milled teeth and bases from pre-polymerized high-pressure PMMA provides superior adhesion. In conventional heat-cured systems, the composite teeth yield the strongest bond. For optimal clinical durability in digital workflows, matched CAD/CAM tooth-based systems should be preferred.

Indexed as

acrylic compositeartificial teethcomputer-aided designcomputer-aided manufacturingpolymethyl methacrylate

Identifiers

PMID41497946
PMCPMC12766538

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.