ArticleClinical ophthalmology (Auckland, N.Z.)2025

The Effect of Orthokeratology Lens Decentration on Ocular and Biomechanical Measurements.

Xiuli Hu, Chenpei Zhao, Weicong Lu, Yuyin Tian, Dongdong Jiang, Wenzhi Ding, Lin Leng

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiuli Hu *Experimental Teaching of Clinical Skills Center, Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Chenpei Zhao *Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People's Republic of China.
Weicong LuSchool of Optometry and Ophthalmology, The Eye Hospital of Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
Yuyin TianEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People's Republic of China.
Dongdong JiangEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People's Republic of China.
Wenzhi DingEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People's Republic of China.
Lin LengEye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People's Republic of China.ORCID 0000-0001-9947-1352

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To investigate the effects of orthokeratology (ortho-K) lens decentration on ocular and biomechanical parameters and analyze the correlation of these parameters with decentration distance. Methods: Thirty eyes of 30 myopic adult subjects, mean age 28.2 years who had worn ortho-K lens for two hours were recruited for this prospective study. Under both the central and eccentric lens fitting conditions, the subjects underwent two rounds of assessments with a week-long interval. The ocular parameters were measured by an IOL Master, whereas the biomechanical parameters were measured by a Corves ST. Differences between measurements were evaluated by one-way ANOVA and a post hoc test. Repeatability was analyzed based on within-subject standard deviation (Sw), repeatability coefficient (RC), intraclass correlation coefficient (ICC), and correlation of variation (CoV). Pearson correlation analysis was employed for correlation analysis. Results: The ocular parameters showed no significant differences, whereas among the biomechanical parameters, the biomechanical corrected intraocular pressure (bIOP) (95% CI 15.8-16.7 mmHg, 14.7-15.6 mmHg, 14.5-15.5 mmHg for baseline, central and eccentric group) and stiffness parameter at first applanation (SPA1) (95% CI 111.7-122.4, 102.3-113.0, 103.9-115.1 for baseline, central and eccentric group) showed significant changes after ortho-K. In all groups, the ocular parameters showed good repeatability with ICC values greater than 0.95 and CoV values lower than 1.3%. By contrast, the biomechanical parameters showed poor repeatability with low ICC values (ie, below 0.7) for the length of flattened cornea at the first and second applanations (A1L and A2L, respectively) and for velocity of corneal apex at the second applanation (A2V) in the baseline group; for A1L, A2L, and bIOP in the central group; and for A1L and A2V in the eccentric group. The correlation analysis showed the positive relationship in A2L between central and eccentric groups. Conclusion: Ortho-K lens decentration did not influence the ocular parameters. However, the biomechanical parameters, the bIOP and SPA1 related to corneal thickness changed after ortho-K.

Indexed as

axial lengthbiomechanical parametersdecentrationorthokeratology

Identifiers

PMID41496876
PMCPMC12766315