Observational studyRespiratory research2026
Detection of nocturnal desaturation and hypercapnia using accelerometer-integrated pulse oximetry: a prospective observational study.
Observational study in Respiratory research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSleep-related hypoventilation, particularly during rapid eye movement (REM) sleep, has been linked to pulmonary hypertension and recurrent exacerbations in individuals with advanced chronic respiratory or neuromuscular diseases. Overnight pulse oximetry (OPO) serves as a valuable screening tool to depict episodic oxygen desaturation resulting from sleep-related hypoventilation. However, differentiating nocturnal desaturation caused by physical activity from that attributable to sleep-related hypoventilation remains clinically challenging. This study aimed to determine whether the integration of accelerometer data with OPO readings can assist in distinguishing exertional nocturnal desaturation from desaturation due to sleep-related hypoventilation.
methodsBetween July 2021 and December 2022, a prospective enrollment was conducted among consecutive individuals with stable chronic respiratory disorders who reported worsening exertional dyspnea. Participants underwent overnight monitoring involving transcutaneous carbon dioxide pressure (PtcCO₂) and pulse oximetry integrated with accelerometer sensors. The number of exertion-associated desaturation events was compared between participant self-reports and acceleration-derived data. Additionally, the diagnostic accuracy of accelerometer-integrated pulse oximetry for detecting episodic nocturnal hypercapnia was assessed using PtcCO₂ monitoring as the reference standard. The primary endpoint was the patient-level diagnostic accuracy of accelerometer-integrated pulse oximetry in detecting episodic nocturnal hypercapnia.
resultsThirty-six individuals were enrolled, with a median age of 78.0 (IQR: 72.0-82.0) years and a mean daytime arterial carbon dioxide pressure (PaCO₂) of 42.4 ± 6.9 mmHg. Of the 89 desaturation events observed, 56 (62.9%) were identified as exertion-related using accelerometer data, including 19 events (21.3%) that were not self-reported. The device demonstrated a sensitivity of 100% (95% CI: 79.6-100%) and a specificity of 75.7% (95% CI: 64.8-84.0%) in identifying episodic nocturnal hypoxia associated with hypercapnia. At the patient level, sensitivity and specificity were 100% (95% CI: 100-100%) and 73.1% (95% CI: 53.9-86.3%), respectively. At the event level, sensitivity and specificity were 100% (95% CI: 79.6-100%) and 75.7% (95% CI: 64.8-84.2%), respectively.
conclusionAmong individuals with suspected sleep-related breathing disorders, accelerometer-integrated pulse oximetry may serve as a valuable tool to distinguish nocturnal desaturation episodes caused by exertion from those due to sleep-related hypoventilation. These findings suggest that accelerometer-integrated pulse oximetry could offer a feasible screening method for detecting sleep-related hypoventilation in outpatient settings lacking access to PtcCO
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.