Clinical evaluation and comparative study of a fully automated erythrocyte osmotic fragility analysis system based on scatter turbidimetry.

Lei Ma, Yueying Huang, Ting Chen, Fan Yang, Xianmin Wang, Fei Xiong, Jingbo Tang, Song Zhang, Yingying Gao

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lei MaDepartment of Medical Laboratory, The Chenjiaqiao Hospital of Shapingba District of Chongqing, Chongqing, 400000, China.
Yueying HuangDepartment of Laboratory Medicine, Peking University Shenzhen Hospital, Shenzhen, 518000, China.
Ting ChenChongqing Medical and Pharmaceutical College, Chongqing, 400000, China.
Fan YangClinical Laboratory Diagnostics, Jiamusi University, Jiamusi, 154007, China.
Xianmin WangClinical Laboratory Diagnostics, Jiamusi University, Jiamusi, 154007, China.
Fei XiongDepartment of Medical Laboratory, The Chenjiaqiao Hospital of Shapingba District of Chongqing, Chongqing, 400000, China.
Jingbo TangShenzhen Lifotronic Technology Co., Ltd, Shenzhen, 518000, China.
Song ZhangShenzhen Lifotronic Technology Co., Ltd, Shenzhen, 518000, China.
Yingying GaoDepartment of Laboratory Medicine, Peoples's Hospital of Chongqing, Banan district, Chongqing, 518000, China. gyyml1076@163.com.

Funding

Chongqing medical scientific research project (2024MSXM137)Chongqing Shapingba District medical scientific research project (Joint project of Chongqing Shapingba District Health Commission and Science and Technology Bureau) (2022SQKWLH018)Joint project of Chongqing Health Commission and Science and Technology Bureau 2024MSXM137
6 · The paper itself

Abstract

Accurate assessment of erythrocyte osmotic fragility (EOF) is essential for diagnosing hemolytic disorders, yet traditional methods are labor-intensive and time-consuming, limiting their clinical efficiency. This study aimed to evaluate the performance of a fully automated EOF analysis system developed by Shenzhen Pumen Technology Co., Ltd., which utilizes scatter turbidimetry, and to determine its accuracy and consistency compared with the conventional spectrophotometric method. A total of 114 whole blood samples were analyzed using the automated system with reagents from Changchun Huili Biotechnology Co., Ltd., and results were compared with those obtained from the Shimadzu UV-2450 spectrophotometer as the reference method. Consistency between the two systems was assessed using linear regression, Kappa statistics, Bland-Altman analysis, and medical decision level bias evaluation. The automated EOF system demonstrated a strong linear correlation with the reference method, achieving a Kappa value of 1.00, indicating complete agreement in classification results. Moreover, 99.11% of data points fell within acceptable ranges, and bias confidence intervals at the medical decision level were below threshold values. These findings indicate that the fully automated EOF system provides stable and reliable results that align with clinical needs and offer high consistency with traditional methods, supporting its potential for broader clinical application and promotion.

Indexed as

ErythrocytesNephelometry and TurbidimetryOsmotic FragilityAdultAutomationFemaleHumansMaleMiddle AgedAutomation systemsClinical performanceConsistency analysisErythrocyte osmotic fragilityScattering nephelometry

Identifiers

PMID41495396
PMCPMC12873172

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.