Evidence map›Paper›PMID 41495252›Full record

ArticleScientific reports2026

NiO/CuO@Graphene oxide-modified electrode for sensitive detection of an antidiabetic drug.

Essam N Labeeb, Mahmoud A Hefnawy, Shymaa S Medany, Eman Yossri Frag

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Essam N LabeebChemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
Mahmoud A HefnawyChemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt. maahefnawy@gmail.com.
Shymaa S MedanyChemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
Eman Yossri FragChemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new, simple, and cost-effective electrochemical sensor was developed for the determination of Sitagliptin phosphate monohydrate (SP) in powder, pharmaceutical tablet form and biological fluids as spiked plasma. Electrochemical sensor used a chemically modified electrode (CME) based on a glassy carbon electrode (GCE) modified with graphene oxide (GO) and nickel/copper oxide nanoparticles (NiO/CuO NPs). The crystalline nature of GO/ (NiO/CuO NPs), the particle size of (NiO/CuO NPs) and the surface topography of the prepared surface were investigated using surface analysis techniques such as X-ray diffraction (XRD), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) combined with energy dispersive X-ray analysis (EDXA) and elemental mapping. Surface characterization revealed that NiO/CuO NPs had an average size of 27.5 ± 2 nm and were uniformly distributed homogenously on the surface of GO. This distribution increased the effective surface area and enhanced electron transfer, confirming the structural and electrochemical advantages of the modified electrode material. The sensor efficiency was validated by different electrochemical techniques such as differential pulse voltammetry (DPV), cyclic voltammetry (CV), and electrical impedance (EIS). The Voltammetric response of SP powder form toward sensor was observed at − 0.1 V in DPV and − 0.055 V in CV, using 0.1 M phosphate-buffered solution (PBS, pH 7.4) as the electrolyte. The linear concentration range for SP in powder form was 0.05–1.071 mM, with a limit of detection (LOD) of 0.0223 mM and a limit of quantification (LOQ) of 0.0677 mM while, for powder in spiked plasma linear range was 0.0295–0.2715 mM, with LOD of 0.0061 mM and LOQ of 0.0185 mM. The diffusion coefficient (D) of 0.614 mM SP in PBS (pH 7.4, 0.1 mol/L) was evaluated using CV at various scan rates and found to be 2.41 × 10⁻⁶ cm²/s, based on the Randles–Sevcik equation. The method was validated by detecting SP in both powder and tablet forms using an Agilent 1200 HPLC system equipped with a UV detector at 266 nm. Statistical calculations such as recovery and precision were carried out to validate the accuracy and reliability of the method. The recovery values for both the electrochemical and HPLC-UV methods ranged from 99% to 101%, while the repeatability and reproducibility of the electrochemical method showed RSD values below 1.5%. The sensor demonstrated good sensitivity and selectivity toward SP, even in the presence of potential interferents such as glucose, ascorbic acid, and metal ions.

Indexed as

CopperElectrochemical TechniquesGraphiteHypoglycemic AgentsNickelSitagliptin PhosphateElectrodesHumansLimit of DetectionTabletsCoppercupric oxidegraphene oxideGraphiteHypoglycemic AgentsNickelnickel monoxideSitagliptin PhosphateTabletsChemically modified electrodeDifferential pulse voltammetryElectrochemical sensorSitagliptin phosphate monohydrate

Identifiers

PMID41495252
PMCPMC12780167

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.