Evidence map›Paper›PMID 41492574›Full record

ReviewCureus2025

Standardizing Quality Metrics for Neuraxial Labor Analgesia: A Quality Improvement Framework for Obstetric Anesthesia.

Shivang S Patel, Nadiya A Persaud, Dean Cirilla, David Vann, Brendan Malik, Mani Vindhya

Abstract readReview
In one paragraph

Review in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shivang S PatelDepartment of Research, Orlando College of Osteopathic Medicine, Winter Garden, USA.
Nadiya A PersaudCollege of Public Health, University of South Florida, Tampa, USA.
Dean CirillaDepartment of Anesthesiology, BayCare Medical Group, Tampa, USA.
David VannDepartment of Anesthesiology, BayCare Medical Group, Tampa, USA.
Brendan MalikDepartment of Anesthesiology, BayCare Medical Group, Tampa, USA.
Mani VindhyaDepartment of Anesthesiology, BayCare Medical Group, Tampa, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Neuraxial labor analgesia, delivered through epidural or combined spinal-epidural techniques, remains the cornerstone of intrapartum pain management. However, variation in quality measurement continues to limit opportunities for benchmarking and systematic improvement. This study aimed to synthesize existing quality measures and propose a standardized obstetric anesthesia quality improvement framework with clear, measurable benchmarks. A targeted review was conducted using predefined inclusion and exclusion criteria to identify organizational guidelines, peer-reviewed literature, and gray literature sources relevant to neuraxial labor analgesia quality metrics, which were then refined through expert consensus. A multidisciplinary panel consisting of attending anesthesiologists, anesthesiology residents, certified registered nurse anesthetists (CRNAs), and certified anesthesiologist assistants (CAAs) reviewed the synthesized evidence, and all benchmarks were finalized through structured discussion and consensus-based decision-making. The resulting framework outlines proposed operational benchmarks across five domains. Access and timeliness were defined as at least 90% of eligible patients receiving neuraxial analgesia within 30 minutes of request, with a median request-to-placement time of 30 minutes or less. Safety metrics included dural puncture rates below 1%, epidural replacement below 5%, maternal hypotension requiring vasopressors below 10%, and elimination of high neuraxial block or epidural-related infection/hematoma as sentinel events. Effectiveness measures targeted adequate pain relief within 20 minutes in at least 95% of cases and conversion to general anesthesia for cesarean delivery below 1%. Documentation and compliance required complete procedural records, checklist use, and pre- and post-procedure pain scores in at least 95% of cases. Patient experience benchmarks included at least 90% satisfaction with pain management and 95% willingness to choose neuraxial analgesia again. Benchmark thresholds were informed by published evidence, national and international recommendations, findings across included sources, and expert consensus. A consolidated, procedure-specific dashboard can align practice expectations, enable transparent benchmarking, and drive continuous improvement. Adoption of this framework can standardize measurement and promote high-quality, patient-centered obstetric anesthesia care.

Indexed as

benchmarkdashboardobstetric anesthesiaquality improvement researchquality metric

Identifiers

PMID41492574
PMCPMC12765509

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.