Evidence map›Paper›PMID 41492532›Full record

ArticleMethodsX2025

A hybrid approach for real-time hand tracking using fiducial markers and inertial sensors.

Ranjeet Bidwe, Shubhangi Deokar, Yash Parkhi, Tanisha Vyas, Nimita Jestin, Utkarsh Kumar, Satviki Budhia, Armaan Jeswani

Abstract read
In one paragraph

Article in MethodsX, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ranjeet BidweDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Shubhangi DeokarDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Yash ParkhiDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Tanisha VyasDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Nimita JestinDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Utkarsh KumarDepartment of Robotics and Automation, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Satviki BudhiaDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
Armaan JeswaniDepartment of Computer Science and Engineering, Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a cost-effective hybrid hand-tracking technique that integrates fiducial marker detection, capacitive touch sensing, and inertial measurement for real-time gesture recognition in immersive environments. The system is implemented on lightweight hardware comprising a Raspberry Pi Zero 2 W and an ESP32, with OpenCV's ArUco marker detection enabling 3D hand pose estimation, capacitive sensors supporting finger-state recognition, and an Inertial Measurement Unit (IMU) providing orientation tracking. Optimizations such as exposure adjustment and region-of-interest processing ensure robust marker detection under variable illumination, while sensor data is transmitted via Bluetooth Low Energy (BLE) and WebSocket protocols for synchronization with external devices. The methodological novelty of this work is highlighted as follows: •High Accuracy Across Modalities: Achieved 3.4 mm localization accuracy, 85-91% orientation accuracy, and ∼2.9 mm hand pose keypoint accuracy, with trajectory fidelity maintained at 80-81%. •Robust Finger-State Recognition: The capacitive sensing module consistently delivered 96.1% accuracy in detecting finger states across multiple runs. •Validated Communication Trade-offs: Latency testing established complementary roles of Wi-Fi (high throughput, ∼467 msg/s) and BLE (low latency, ∼50 ms, >98% reliability) for real-time applications. By fusing multiple sensing modalities, the method delivers enhanced accuracy, responsiveness, and stability while minimizing computational overhead. The system provides a reproducible, modular, and scalable solution suitable for VR/AR interaction, assistive technology, education, and human-computer interaction.

Indexed as

ArUco markersBluetooth Low Energy (BLE)Capacitive touch sensorsComputer visionFiducial markersHand trackingInertial measurement unit (IMU)OpenCV

Identifiers

PMID41492532
PMCPMC12765117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.