Evidence map›Paper›PMID 41492143›Full record

ArticleArthroplasty (London, England)2026

Consistently high accuracy of digital 2D templating in total knee arthroplasty across different levels of surgical training.

Moses K D El Kayali, Fahad Imtiaz, Luis V Bürck, Sebastian Braun, Clemens Gwinner, Lorenz Pichler, Rosa Berndt

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Moses K D El KayaliCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany. moses.elkayali@charite.de.
Fahad ImtiazDepartment of Orthopedics and Trauma-Surgery, Berlin Jewish Hospital, Berlin, 13347, Germany.
Luis V BürckCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany.
Sebastian BraunCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany.
Clemens GwinnerCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany.
Lorenz PichlerCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany.
Rosa BerndtCenter for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, Berlin, 10117, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy of two-dimensional (2D) digital templating in primary total knee arthroplasty (TKA) and assess whether surgical training level affects templating accuracy.

methodsA total of 424 patients who underwent primary TKA with preoperative 2D digital templating using the Attune system were retrospectively analyzed. Templating was performed in TraumaCad (Brainlab AG) by junior residents (< 3 years of training), senior residents (≥ 3 years), or board-certified orthopaedic surgeons. Planned and implanted component sizes were compared, and accuracy was assessed as exact matches and deviations of ± 1, ± 2, and ± 3 sizes. Pearson correlation analysis was used to assess the association between planned and implanted sizes. One-way ANOVA was used to compare mean absolute deviation across training levels. Additionally, the proportion of cases with a deviation greater than ± 1 size was calculated for both components across experience levels and compared using chi-square tests.

resultsA total of 424 patients (61% female) were included. The median planned component sizes were 6 (IQR, 5-7) for the femoral and 6 (IQR, 5-7) for the tibial component; the median implanted sizes were 6 (IQR, 5-7) and 6 (IQR, 4-7), respectively. Planned and implanted sizes were very strongly correlated for both femoral (r = 0.864; P < 0.001) and tibial components (r = 0.841; P < 0.001). Templating accuracy was high, with 92.7% of femoral and 88.7% of tibial components within ± 1 size. No significant differences in correlation strength or mean absolute deviation were observed across training levels (P > 0.05). The proportion of cases with > ± 1 size deviation was low across all groups and did not differ significantly between training levels for either component (femoral: P = 0.874; tibial: P = 0.791).

conclusion2D digital templating for primary TKA demonstrated high accuracy, with reliable prediction within a ± 1 size range and no significant influence of surgical training level. These findings support its continued clinical use and confirm that templating can be reliably performed by residents at all stages of training. Video Abstract LEVEL OF EVIDENCE: Level III, diagnostic study.

Indexed as

Digital templatingOsteoarthritisPreoperative planningTotal knee arthroplasty

Identifiers

PMID41492143
PMCPMC12772012

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.