ArticleBMC oral health2026
Sleeve material, height, and drill surface changes in guided endodontics: Vicker's hardness and scanning electron microscope evaluation (A pilot study).
Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundGuided endodontic access uses a CBCT-derived template with a guide sleeve to direct the drill for precise canal location, particularly in calcified teeth. This technique is more conservative, time-efficient, and accurate than conventional methods. Guide sleeves are fabricated from various materials (e.g., zirconia ceramic, cobalt-chromium alloy, titanium alloy, or 3D-printed resin), but their hardness and durability under drilling stress are not well characterized. However, guiding long, narrow drills through sleeves may generate excess heat due to friction between the surfaces, potentially causing tool wear. Studies in implant dentistry show significant drill wear with repeated use, but the effects of sleeve material and sleeve height on endodontic drill wear remain uncharacterized. This study used Scanning Electron Microscopy (SEM) to examine drill surface changes after guided Minimally Invasive Endodontic Access (MIEA) with different sleeve materials (resin, zirconia [Y-TZP], Ti-6Al-4 V, CoCr alloy) and heights. This study evaluated Sleeve Material, Height, and Drill Surface Changes in Guided Endodontics through the Vickers Hardness Test and Scanning Electron Microscope.
methodsIn vitro, 30 guide sleeves (10 sizes: 3 mm, 5 mm, 7 mm; 4 different materials) fit a 1.5 mm carbide bur with limited clearance. Sleeve materials tested in the current study are dental photopolymer resin, Y-TZP, Co-Cr, and Ti-6Al-4 V. Before and after drilling, the sleeve hardness was measured through Vickers Hardness Test (HV0.2). Hardness variations (ΔVHN) were determined. A one-way ANOVA was used to assess hardness among materials and sleeve heights, with significance at p < 0.05. Additionally, three teeth were drilled under irrigation by one group of standardized high-speed carbide drills per guide. Cleaning and imaging of drill tips and flutes were done using a SEM (1000x magnification). Two examiners rated wear as Grade 0 (no wear), Grade 1 (minor blunting or edge rounding), or Grade 2 (severe chipping or edge loss). Five drills showed a noticeable thermal discoloration ("burn marks") and were included in the analysis. This study is a pilot study or an early feasibility study. The data will be analysed using a Descriptive approach.
resultsWhile zirconia sleeves had the highest hardness rating (mean ~ 1392 HV pre-drilling; ~1389 HV post-drilling), resin sleeves had the lowest (~ 6 to 7 HV both pre- and post-drilling), while CoCr and Ti-alloy sleeves had intermediate hardness (~ 315 and ~ 405 HV). ANOVA showed significant differences in material type (p < 0.001), but no significant effect of sleeve height on hardness (p > 0.8). Due to modest hardness variations, drilling cycles do not strain-harden or soften the sleeve. Four drills (30%) exhibited Grade 1 wear. Six drills (70%) had Grade 2 wear. Medium- and short-resin sleeves showed Grade 1 wear, whereas Zirconia, Titanium, and CoCr showed Grade 2 wear. Short sleeves produced Grade 1 wear, while medium/long sleeves frequently caused Grade 2 wear. Five drills with burn marks were classified as Grade 2. Overall, Grade 2 wear was observed in 60% of drills, and Grade 1 in 40%.
conclusionsSleeve hardness was primarily determined by the material type, with sleeve height having no significant effect. Zirconia guide sleeves were harder than CoCr, Ti, and resin, and may also offer greater wear resistance and durability for guided endodontic template sleeves. All tested materials maintained their hardness after simulated guided access drilling. Guided minimally invasive endodontic access drill wear was considerable with static sleeves. The majority of the drills experienced thermal damage and were classified as Grade 2 surface damage. Drill abrasion was notably increased when using resin, zirconia, and cobalt-chromium (CoCr) sleeves, attributed to their greater hardness, wear resistance, and sleeve height. While resin sleeves may help reduce wear during minimally invasive guided endodontics, the absence of an effective root canal irrigation system limits cooling efficiency. Clinicians must be aware that more rigid guides and sleeve systems may demand additional measures, such as optimized irrigation or intermittent drilling, to avoid thermal and mechanical damage. Proper selection of guide sleeves and implementation of effective cooling mechanisms are essential to the success of guided endodontic procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.