Evaluation of dose rate and gantry speed variations in volumetric modulated Arc therapy optimization algorithms for a modern linear accelerator.

Venugopal Sundaram, David Khanna, Mohandass Palanisamy

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Venugopal SundaramDivision of Physical Sciences, Karunya Institute of Technology and Sciences (Deemed University), Karunya Nagar, Coimbatore, Tamilnadu, 641114, India.ORCID http://orcid.org/0009-0006-8533-2670
David KhannaDivision of Physical Sciences, Karunya Institute of Technology and Sciences (Deemed University), Karunya Nagar, Coimbatore, Tamilnadu, 641114, India. davidkhanna@karunya.edu.ORCID http://orcid.org/0000-0001-5255-7212
Mohandass PalanisamyDepartment of Radiation Oncology, Fortis Hospital, Mohali, Punjab, 160062, India.ORCID http://orcid.org/0000-0002-3832-9616

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis study investigates the impact of gantry speed (GS) and dose rate (DR) variations on VMAT RapidArc plan quality and delivery using the Photon Optimizer (PO) and Progressive Resolution Optimizer (PRO) algorithms in the Varian TrueBeam LINAC. MATERIALS AND

methodsFive treatment sites (brain, head and neck, Hodgkin’s lymphoma, advanced lung, and cervix) were planned using PO and PRO algorithms. Plans were generated with varying GS (0.5 and 6.0 deg/s) and DR (100–600 MU/min) combinations, resulting in 24 plans per site. Plan quality was assessed using DVH parameters and isodose distributions. Technical delivery aspects, including MU/deg, total MU, DR, and GS patterns, were analyzed. Trajectory log files provided data on planned vs. delivered dose, gantry angle deviations, and MLC position deviations. Pre-treatment QA was performed using Portal dosimetry, with a 3%/3 mm gamma criterion.

resultsBoth PO and PRO algorithms demonstrated similar dose distributions and PTV coverage D95% (differences < 3%) across all sites and GS/DR combinations. Minor variations in OAR doses were observed. Maximum MU/deg limits varied with GS and DR levels, with PO showing higher limits at slower GS. PO generally exhibited higher MU/deg and DR compared to PRO. Gantry speed remained constant at the set value during delivery. Trajectory log analysis confirmed accurate dose delivery, with deviations in gantry angle and MLC positions within tolerances. Portal dosimetry yielded high gamma passing rates (> 98.6%) for both algorithms across all sites and GS/DR combinations, indicating accurate dose calculation and delivery.

conclusionThis study provides valuable insights into the technical aspects of VMAT delivery and supports the clinical use of both PO and PRO algorithms for a wide range of treatment sites and delivery conditions. Truebeam LINAC controller systems data confirmed any variation of GS and DS deliver better accuracy for both optimizers. Current Truebeam platform LINAC can deliver any extreme mechanical limits without causing or reducing accuracy plans can be delivered very accurately.