ArticleFrontiers in bioengineering and biotechnology2025
Verification, validation, and uncertainty quantification of finite element analysis results for pedicle screw assemblies under ASTM F1717 flexion and extension testing.
Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The Development of a Syringe-Based Insulin Applicator Using a Biodesign-Based Methodology.Biomimetics (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: This study conducted verification, validation, and uncertainty quantification of finite element analysis (FEA) results for pedicle screw assemblies subjected to static flexion and extension loading conditions, in accordance with the ASTM F1717-15 standard. Methods: Four screw configurations and two material types, titanium alloy and titanium grade 23, were modeled to replicate the experimental setup. Simulations incorporated five types of contact conditions at the screw-block interface: frictionless; coefficient of friction (COF) of 0.1, 0.2, or 0.5; and bonded. Results: Experimental results demonstrated high repeatability, with maximum deviations of 6.4% for stiffness, 9.1% for yield displacement, 7.2% for yield force, and 7.5% for force at 20 mm displacement. The FEA results qualitatively captured the experimental trends but quantitatively overestimated mechanical responses, particularly under bonded contact conditions. The largest prediction errors were 19.8% for stiffness, 21.5% for yield force, and 18.4% for force at 20 mm, while the greatest deviation in yield displacement, 14.2%, occurred under frictionless conditions. When targeting an ASME VandV 40 Level 3 agreement (difference <10%), we found that no single interface model satisfied all validation metrics across screws and loading modes. When construct stiffness and force at 20 mm were prioritized as primary validation metrics, COF values in the range 0.10-0.20 yielded the most consistent agreement with experiment. Sensitivity analysis revealed that force and stiffness outputs were highly influenced by contact assumptions, whereas displacement outputs exhibited moderate sensitivity. Discussion: These findings highlight the importance of accurately defining contact conditions and experimentally characterizing interface behavior. To ensure predictive accuracy and regulatory relevance, validated friction models should be applied and contact parameters precisely calibrated, which can enhance the credibility of spinal biomechanics simulations. Relative to prior F1717-based simulations, this work quantifies the dominant impact of interface modeling and provides actionable parameter bounds for validation (μ = 0.10-0.20 for the tested constructs).