Evidence map›Paper›PMID 41484989›Full record

ArticleJournal of orthopaedic surgery and research2026

Modeling and simulation of a porous mobility total ankle arthroplasty implant: enhancing bone-in growth and reducing micromotion for improved fixation.

Mohamed Hassan, Maysa Aljohany, Abdullah H Alzahrani, Hadeel Alsirhani

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohamed HassanDepartment of Engineering, School of Computing and Engineering, University of Huddersfield, Huddersfield, UK.ORCID http://orcid.org/0009-0005-3298-386X
Maysa AljohanyDepartment of Health Rehabilitation Sciences, Faculty of Applied Medical Sciences, University of Tabuk, Tabuk, Saudi Arabia. maljihani@ut.edu.sa.ORCID http://orcid.org/0009-0008-3350-7963
Abdullah H AlzahraniDepartment of Health Rehabilitation, College of Applied Medical Sciences at Shaqra, Shaqra University, Shaqra, Saudi Arabia.ORCID http://orcid.org/0000-0002-4252-8255
Hadeel AlsirhaniDepartment of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Jouf University, Jouf, Saudi Arabia.ORCID http://orcid.org/0009-0000-8405-1582

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPorous implant designs have been introduced in total ankle replacement (TAR) to enhance bone ingrowth and long-term fixation. However, their immediate mechanical stability remains a concern, this study aimed to evaluate and compare the biomechanical behavior of porous and non-porous TAR stem designs under physiological loading using finite element analysis. METHODS AND

resultsThree-dimensional models of both designs were conducted using SolidWorks and analyzed in ANSYS. The proximal tibia was fully constrained in all degrees of freedom, and an axial compressive load of 3414 N was applied to simulate stance-phase conditions. The non-porous implant exhibited a maximum contact pressure of 11.5 MPa and micromotion of 49.6 µm, while the porous implant showed higher peak contact pressure (83.3 MPa) and micromotion (129.4 µm). Stress distribution in the non-porous model was more uniform, whereas localized stress concentrations appeared around the porous stem regions. Peri-implant cancellous in non-porous design generated a peri-implant von Mises stress of 9.54 MPa, whereas the porous model increased these values to 67.3 MPa.

conclusionPorosity enhanced mechanical stimulus to the surrounding cancellous bone and may support improved long-term osseointegration by reducing stress shielding; however, it also produced substantially higher micromotion and contact pressure, indicating compromised primary stability. The localized stress peaks around pore regions highlight the need for balanced implant stiffness and optimized pore architecture to prevent early instability while still promoting bone ingrowth.

Indexed as

Ankle JointArthroplasty, Replacement, AnkleBone DevelopmentComputer SimulationJoint ProsthesisProsthesis DesignBiomechanical PhenomenaFinite Element AnalysisHumansPorosityStress, MechanicalTibiaBone-implant interfaceContact pressureFinite element analysisMicromotionPorous implantTotal ankle replacement

Identifiers

PMID41484989
PMCPMC12849557

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.