Evidence map›Paper›PMID 41480660›Full record

ArticleDiabetes, obesity & metabolism2026

Performance of continuous glucose monitoring systems (CGMs) during commercial flights in T1DM: A within-subject comparative pilot study.

Renald Meçani, Silvia Basta, Petra M Baumann, Monika Cigler, Omaima El Hakouni, Daniel A Hochfellner, Fariba Shojaee-Moradie, Ka Siu Fan, Dietrich Tews, Thomas R Pieber and 5 more

Abstract readComparative Study
In one paragraph

Article in Diabetes, obesity & metabolism, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Technology in Diabetes: A Year in Review.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2026
    Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Renald MeçaniDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0003-2697-8544
Silvia BastaDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0009-0008-5234-7547
Petra M BaumannDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0002-7665-0929
Monika CiglerDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0001-5827-7991
Omaima El HakouniDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0009-0009-1616-6711
Daniel A HochfellnerDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0003-4872-8861
Fariba Shojaee-MoradieCEDAR Centre, Royal Surrey County Hospital, Guildford, UK.ORCID https://orcid.org/0000-0002-3514-0447
Ka Siu FanCEDAR Centre, Royal Surrey County Hospital, Guildford, UK.ORCID https://orcid.org/0000-0002-0861-1944
Dietrich TewsDiabetes Center Dr. Tews, Gelnhausen, Germany.ORCID https://orcid.org/0000-0002-8548-1709
Thomas R PieberDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0003-3554-0405
David Russell-JonesCEDAR Centre, Royal Surrey County Hospital, Guildford, UK.ORCID https://orcid.org/0000-0002-9490-2480
Chantal MathieuKU Leuven, Leuven, Belgium.ORCID https://orcid.org/0000-0002-4055-5233
Gerd KoehlerDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0009-0008-4749-7639
Julia K MaderDivision of Endocrinology and Diabetology, Department of Internal Medicine, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0001-7854-4233
EASA Diabetes Consortium

Funding

EASA - European Union Aviation Safety AssociationÖDG - Österreichische Diabetesgesellschaft
6 · The paper itself

Abstract

aimsContinuous glucose monitoring (CGM) systems are increasingly used, but their accuracy under flight-conditions remains insufficiently studied. We assessed sensor accuracy of four CGMs during in-flight (mid-haul) and ground conditions. MATERIALS AND

methodsParticipants (n = 20) wore four sensors (Abbott Libre 3, Dexcom G7, Medtronic Simplera, and Sinocare iCan i3) in parallel, inserted 1 day prior to experiment. Capillary reference measurements were performed every 30 min. Accuracy evaluation included: proportion of CGM values within 10% of comparator glucose levels >100 mg/dL or within 10 mg/days of comparator levels ≤100 mg/dL (%10/10), along with %20/20 agreement rates, mean absolute relative difference (MARD), Consensus error grid.

resultsTwenty participants with type 1 diabetes (age: 37.9 ± 12.8 years, HbA1c: 52.3 ± 4.9 mmol/mol, diabetes duration 19.25 ± 10.6 years) were included in the analysis. Data from 297 sensors with 3473 matched pairs (G7/Libre3/Simplera/i3) were analysed. The overall MARDs were: 9.5% ± 3.3% (G7), 9.6% ± 3.8% (Libre3), 19.9% ± 6.2% (Simplera) and 15.7% ± 6.6% (i3). Overall %20/20 and %10/10 agreement rates were 90.6%/70.2% (G7), 90.8%/66.8% (Libre3), 63.6%/37.8% (Simplera) and 72.5%/42.2% (i3) respectively. The proportion of values in Zones A and B of the Consensus error grid was 98.9% (G7), 99.0% (Libre 3), 94.5% (Simplera) and 97.5% (i3). Prandial state and flight phase had limited influence on the relative performance ranking of the devices.

conclusionsG7 and Libre3 showed consistently higher accuracy and clinical reliability across various phases of flight and ground conditions. Simplera and i3 exhibited greater variability in accuracy. These findings suggest that while modern CGMs could support diabetes management in aviation, individual system performance may differ under specific operational conditions.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1AdultAircraftContinuous Glucose MonitoringFemaleGlycated HemoglobinHumansMaleMiddle AgedPilot ProjectsReproducibility of ResultsBlood GlucoseGlycated HemoglobinaviationCGMdiabetesinsulinpilotstechnology

Identifiers

PMID41480660
PMCPMC12890742

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.