Evidence map›Paper›PMID 41480224›Full record

ArticleWorld journal of gastrointestinal oncology2025

Exploring the improvement effect of intestinal network monitoring system on intestinal preparation quality of colonoscopy.

Mei-Juan Xi, Yan-Ping Gong, Jian Tao, Fang Li, Min-Yi Xu, Xing Gu, Han Bao, Sheng Jiang, Bing Xu

Abstract read
In one paragraph

Article in World journal of gastrointestinal oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mei-Juan XiDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Yan-Ping GongDepartment of Anesthesiology, Hainan Hospital, General Hospital of the People's Liberation Army, Sanya 572000, Hainan Province, China.
Jian TaoDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Fang LiDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Min-Yi XuDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Xing GuDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Han BaoDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Sheng JiangDepartment of Gastroenterology, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu 215500, Jiangsu Province, China.
Bing XuDepartment of Gastroenterology, Danyang Traditional Chinese Medicine Hospital, Danyang 212300, Jiangsu Province, China. iq3431@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundColonoscopy quality relies heavily on adequate bowel preparation, yet traditional methods often result in suboptimal compliance. Emerging network-based monitoring systems offer promise for improving both preparation quality and patient cooperation, potentially enhancing clinical outcomes.

aimTo evaluate the effectiveness of an intestinal network monitoring system in enhancing the quality of bowel preparation for colonoscopy and its impact on patient psychological and physiological responses, compliance, and adverse event rates.

methodsBetween July 2019 and July 2020, 800 enteroscopy patients who met the inclusion criteria in the outpatient clinic of the gastroenterology department of our hospital were randomly divided into 400 cases each in the experimental group (network monitoring group) and the control group (verbal + written preaching group), and the psychological and physiological stress response situation, colon Boston Bowel Preparation Scale, enteroscopy to blindness, arrival time to blindness, and polyp detection rate of the patients were compared before and after the intervention, compliance and adverse reactions were compared.

resultsThere was no difference in anxiety and depression scores, heart rate and systolic blood pressure between the groups before the intervention (

conclusionThe Bowel Network Monitoring System has potential clinical promotion value in improving the quality of colonoscopic bowel preparation, which can effectively alleviate patient anxiety and depression, improve the quality of colonoscopic bowel preparation and patient compliance, and has a high degree of safety.

Indexed as

Adverse events reductionBowel preparation qualityColonoscopyIntestinal network detection systemIntestinal preparation qualityStress response

Identifiers

PMID41480224
PMCPMC12754311

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.