ArticleMicrosystems & nanoengineering2026
Skin-conformal PMN-PT ultrasonic sensor for cuffless blood pressure sensing via eutectic solder integration.
Article in Microsystems & nanoengineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Wearable ultrasonic systems are emerging as promising tools for noninvasive cardiovascular monitoring, enabling the real-time assessment of vascular dynamics without the need for cuff-based measurements. However, the integration of high-performance piezoelectric materials into flexible, skin-conformal arrays poses challenges in terms of mechanical stretchability, acoustic fidelity, and scalability. In this study, we present a flexible 5 × 4 ultrasonic transducer array (UTA) based on 1-3 lead magnesium niobate-lead titanate (PMN-PT) composite elements for continuous blood pressure monitoring. To achieve reliable integration, we employed a dual-sided eutectic solder bonding method using an Sn-Bi alloy to ensure low-temperature attachment without depolarization. The fabricated UTA operates at a center frequency of 6.0 MHz with an acceptance angle of 45°, enabling acoustic signal acquisition under varying angular conditions. Time-of-flight simulations and in vitro testing of vascular phantoms demonstrated the accurate tracking of vessel diameters and the estimation of real-time blood pressure. The UTA achieved systolic and diastolic pressure measurements within 4 mmHg of those of a commercial reference sensor. These results highlight the feasibility of scalable and flexible ultrasound systems for wearable hemodynamic sensors, suggesting their potential for next-generation point-of-care diagnostics.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.