SynthesisBMJ open2025
Performance of artificial intelligence in breast cancer screening programmes: a systematic review.
Synthesis in BMJ open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Bridging Clinical Appropriateness and Safe Use: Considerations for Large Language Models in Breast Cancer Advice.Journal of medical imaging and radiation oncology · 2026Article
- Zero-Shot Domain Adaptation of 2D Mammography Lesion Detection Model for 3D Breast CT Malignancy Detection.Cancers · 2026Article
- ATP5F1B promotes breast cancer progression through ERK associated metabolic reprogramming.Molecular biology reports · 2026Article
- Emerging Approaches in Breast Cancer: From Molecular Mechanisms to Diagnosis and Therapeutic Strategies.Oncology research · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWith growing interest in applying artificial intelligence (AI) to population breast cancer screening, the evidence base has expanded rapidly. This systematic review aims to systematically review and summarise the published evidence on the use of AI in breast cancer screening.
designWe conducted a systematic review of primary studies assessing AI for screening mammography, extracting test-accuracy metrics (sensitivity, specificity, recall and cancer detection rates) and workflow outcomes. DATA SOURCES: We searched the Cochrane Breast Cancer Group Specialised Register, Cochrane CENTRAL, PubMed, Embase (Elsevier), Scopus, ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform from January 2012 to June 2025; we also screened reference lists of included studies and relevant reviews. No language restrictions were applied. ELIGIBILITY CRITERIA: Primary studies evaluating AI for screening mammography (digital mammography or digital breast tomosynthesis) in asymptomatic women, assessing AI as a standalone reader or AI-assisted radiologist workflows versus radiologists alone. Eligible designs included randomised trials, prospective paired reader studies, real-world implementation/registry cohorts, retrospective cohorts and multireader-multicase reader studies conducted in population-based or opportunistic screening settings. Key outcomes included diagnostic accuracy metrics (eg, sensitivity, specificity, Area Under the Curve (AUC) and/or programme metrics (cancer detection rate (CDR), recall/abnormal interpretation rate, positive predictive value, arbitration/workload). We excluded protocols, pilot/feasibility studies, case reports, editorials and studies without relevant accuracy or screening outcomes. DATA EXTRACTION AND SYNTHESIS: Two independent reviewers extracted data and assessed risk of bias. Study quality was appraised with Quality Assessment of Diagnostic Accuracy Studies-2 and an AI-specific critical appraisal tool, and findings were synthesised narratively with stratification by study design and AI integration role.
results31 studies met the inclusion criteria, encompassing randomised controlled trials, prospective paired-reader studies, registry-based implementations and retrospective simulations, representing more than two million screening examinations across Europe, Asia, North America and Australia. When used as a second reader or within double-reading workflows, AI generally maintained or modestly increased sensitivity (up to +9 percentage points (PP)) while preserving or improving specificity. Triage and decision-referral configurations delivered the greatest operational benefit, reducing reading volumes by 40-90% while maintaining non-inferior cancer detection when thresholds were conservatively calibrated. Stand-alone AI achieved AUC values comparable to radiologists and similar cancer detection in real-world, non-enriched cohorts, although interval-cancer follow-up remains incomplete in several datasets. In prospective randomised evidence, including the Mammography Screening with Artificial Intelligence trial (MASAI) trial, AI-supported screening achieved higher CDRs (6.4 versus 5.0 per 1000; p=0.0021) with stable or reduced false-positive and recall rates. Across implementation and simulation settings, integration of AI reduced radiologist workload substantially, with triage and band-pass approaches reducing the number of reads by approximately 40-90%. Overall certainty is limited by heterogeneity across study designs, reliance on enriched datasets for some accuracy estimates and incomplete interval-cancer follow-up in several major studies.
conclusionContemporary AI systems show diagnostic performance that is broadly comparable to radiologists and can substantially reduce reading workload, particularly when used as a second reader or triage tool. Emerging prospective evidence supports their safe integration in these roles, although transparent reporting, standardised evaluation and long-term population studies are still required before considering AI as a stand-alone reader. AI may improve workflow efficiency and possibly cancer detection, but definitive evidence on safety, especially interval cancer outcomes, remains essential.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.