Evidence map›Paper›PMID 41473766›Full record

ArticleJournal of biomedical optics2026

Imaging lymphatic function and inflammation response through hypoxia via endogenous biomarker.

Marien I Ochoa, Xu Cao, Matthew S Reed, Eduard Matkovic, Weifeng Zeng, Samuel O Poore, Brian W Pogue

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Marien I OchoaUniversity of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, United States.ORCID https://orcid.org/0000-0001-6427-4447
Xu CaoUniversity of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, United States.
Matthew S ReedUniversity of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, United States.ORCID https://orcid.org/0009-0002-2134-5844
Eduard MatkovicUniversity of Wisconsin-Madison, Department of Pathology, Madison, Wisconsin, United States.ORCID https://orcid.org/0000-0003-1492-5170
Weifeng ZengUniversity of Wisconsin School of Medicine and Public Health, Department of Surgery, Madison, Wisconsin, United States.
Samuel O PooreUniversity of Wisconsin School of Medicine and Public Health, Department of Surgery, Madison, Wisconsin, United States.ORCID https://orcid.org/0000-0002-6029-3306
Brian W PogueUniversity of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, United States.ORCID https://orcid.org/0000-0002-9887-670X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: The lymphatic system, crucial for immune function and fluid balance, is difficult to study due to its nearly invisible channels and passive movements. Despite its importance, real-time, noninvasive lymphatic imaging is limited and often relies on exogenous agents. A largely overlooked feature of the lymphatic system is its natural hypoxia, arising because lymphatic vessels and nodes are distant from oxygen-rich blood and serve as a waste reservoir and from amplifying factors such as inflammation. This hypoxia has been linked to lymphangiogenesis and cancer metastasis. Aim: We introduce a method for real-time macroscopic imaging of lymphatic function and response to inflammation, through the intrinsic hypoxia transients that occur in lymphatic structures. Approach: The naturally hypoxic environment of the lymphatic system was imaged Results: Lymphatic pumping frequency changed with increasing wound severity, and hypoxia appeared in sentinel nodes near tumors. Cyclical pumping occurred at edema sites and in wound and tumor-adjacent nodes. Uninjured anesthetized mice showed little contrast, whereas awake mice exhibited hypoxia localized to lymph nodes. Microscopy and IHC confirmed PpIX and hypoxia presence in nodes, tumors, and wounds, localized to macrophages and T cells. Conclusions: Unlike injection-based regional lymph node mapping, DF hypoxia imaging appears to provide a natural whole-body contrast mechanism, highlighting its potential for visualizing lymphatic function and associated hypoxia dynamics. This original documentation of lymphatic hypoxia has potential applications in surgical guidance, tracking of metastatic tumors, and immune response tracking.

Indexed as

HypoxiaInflammationLymphatic SystemLymphatic VesselsOptical ImagingAnimalsBiomarkersFemaleMiceMice, Inbred C57BLPancreatic NeoplasmsBiomarkersfluorescence imaginglymphatic functionmedical imagingoxygen sensingsentinel node detection

Identifiers

PMID41473766
PMCPMC12747121

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.