Evidence map›Paper›PMID 41473070›Full record

ArticleJTCVS open2025

Simulation-guided design of leaflet height in bicuspidization of the aortic valve.

Alexander D Kaiser, Perry S Choi, Amit Sharir, Alison L Marsden, Michael R Ma

Abstract read
In one paragraph

Article in JTCVS open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alexander D KaiserDivision of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.
Perry S ChoiDivision of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.
Amit SharirDivision of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.
Alison L MarsdenStanford University, Cardiovascular Institute, Stanford, Calif.
Michael R MaDivision of Pediatric Cardiac Surgery, Department of Cardiothoracic Surgery, Stanford University, Stanford, Calif.

Funding

Optimizing Congenital Aortic Valve Surgery with Simulation-Guided DesignK25HL175208 · NHLBI · STANFORD UNIVERSITY · PI Alexander D Kaiser · 2024 to 2026
$545k
NHLBI NIH HHS K25 HL175208
6 · The paper itself

Abstract

Background: Bicuspidization repair is typically applied to severe congenital aortic valve lesions. Increasingly, this repair is recognized as an effective and durable surgical approach. The consequences of postoperative leaflet geometry in this repair are relatively unstudied, especially compared with current understanding of optimal geometry for a trileaflet valve. In this work, a computational approach was systematically applied to study the effect of changes in leaflet geometric height in symmetric bicuspidization repair. Methods: Eight model valves with 4 geometric heights spanning a range of typically observed values were constructed at 2 free-edge lengths. Heights varied when loaded in diastole from approximately one-half the annular diameter to just below the annular diameter. Fluid-structure interaction simulations were performed to study the coupled dynamics of the valve and blood. Models were evaluated for stenosis, regurgitation, hemodynamics, mechanics, and diastolic gross morphology. Results: Cases with loaded geometric height 0.64 to 0.79 times the annular diameter showed the overall best performance, with a coaptation reserve of 4 to 7 mm. Cases with geometric height approximately one-half the annular diameter showed severe regurgitation. Cases with geometric height 0.86 to 0.95 times the annular diameter showed less "crisp" coaptation alignment and the appearance of excessive leaflet material. Conclusions: The intermediate range of geometric height appeared best, with insufficient height causing regurgitation. More geometric height was not always clearly better, as excessively tall leaflets showed less alignment in the coaptation regions.

Indexed as

aortic valve repairaortic valve simulationsbicuspidizationcongenital aortic valvesimulation-guided design

Identifiers

PMID41473070
PMCPMC12745109

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.