ArticleVeterinary sciences2025
Accuracy of Three-Dimensionally Printed, Patient-Specific Drill Guides for Implant Placement in Canine Cervical Vertebrae: A Cadaveric Study.
Article in Veterinary sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The objective of this study was to assess the accuracy of autoclavable, three-dimensionally (3D) printed drill guides (3DPG) created with a rapid printing protocol and utilized by both an experienced and inexperienced surgeon in constraining the trajectory of drill tracts to intended corridors within canine cervical vertebrae. The 3DPG were designed using computed tomographic (CT) images of six complete cadaveric canine cervical vertebral columns and used to create drill tracts in all vertebrae by both an experienced and a novice surgeon. Repeat CT imaging was used to assess the entry point (EPD) and angular deviation (AD) of the actual versus planned drill tracts. Unintended cortical bone violations were also assessed. A total of 80 3DPG were used to create 144 drill tracts in 42 vertebrae. The overall mean EPD was 1.1 mm (median 0.9 mm, range 0.1-5.1 mm) and the overall mean AD was 7.3° (median 5.2°, range 0.5-33.8°). There were no differences in overall EPD (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.