Assessing the Validity and Reliability of a Single Lumbar-Mounted IMU System for Gait Analysis.

Alfredo Lerín-Calvo, Giuseppe Prisco, Elena Fernández-Maza, Marta Núñez-González, Gema Santiago-Lorrio, Leandro Donisi, Sergio Lerma-Lara

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alfredo Lerín-CalvoGrupo de Investigación de Neurociencias Aplicadas a la Rehabilitación (GINARE), 28293 Alcorcón, Spain.ORCID 0000-0002-7337-8747
Giuseppe PriscoDepartment of Medicine and Health Sciences, University of Molise, 86100 Campobasso, Italy.ORCID 0009-0002-1981-5843
Elena Fernández-MazaDepartment of Physiotherapy, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Aravaca, 28023 Madrid, Spain.
Marta Núñez-GonzálezDepartment of Physiotherapy, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Aravaca, 28023 Madrid, Spain.
Gema Santiago-LorrioDepartment of Physiotherapy, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Aravaca, 28023 Madrid, Spain.
Leandro DonisiDepartment of Advanced Medical and Surgical Sciences, University of Campania Luigi Vanvitelli, 80138 Naples, Italy.ORCID 0000-0002-9746-2265
Sergio Lerma-LaraDepartment of Physiotherapy, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, Aravaca, 28023 Madrid, Spain.ORCID 0000-0001-9382-3855

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable inertial sensors offer a practical alternative to gold-standard optoelectronic systems for gait analysis, though their validity remains uncertain due to sensor placement. This study examined the intra-rater and inter-rater reliability and the concurrent validity of a single lumbar-mounted inertial measurement unit (Baiobit, BTS Bioengineering, Garbagnate Milanese, Italy) compared with a 3D optoelectronic system (SMART-DX 6000, BTS Bioengineering). Thirty healthy adults walked along an 8 m walkway at a self-selected speed, and seven spatiotemporal gait parameters (cadence, velocity, stride length, step length, stance, swing, and single-support phases) were computed by both systems. Reliability and validity were assessed using intraclass correlation coefficients (ICC), standard error of measurement, minimum detectable change, paired tests, Spearman correlation, Passing-Bablok regression, and Bland-Altman analysis. Baiobit showed intra- and inter-rater ICCs of 0.53-0.90 and 0.66-0.88, respectively. Bland-Altman results indicated non-significant biases for global parameters (velocity: -0.06 m/s; cadence: 1.11 steps/min), whereas spatial measures showed significant biases (stride length: 0.11 m; step length: 0.06 m). Gait phase parameters demonstrated low correlations (r = 0.08-0.11) and proportional systematic errors. Overall, the Baiobit system provided reliable and valid estimates of global spatiotemporal parameters but lacked precision for gait phase metrics, underscoring limitations that currently prevent it from fully replacing optoelectronic systems.

Indexed as

GaitGait AnalysisLumbosacral RegionAdultBiomechanical PhenomenaFemaleHumansMaleReproducibility of ResultsWalkingWearable Electronic DevicesYoung Adultgait analysisinertial measurement unitmotion capturereliabilityspatiotemporal parametersvalidity

Identifiers

PMID41471639
PMCPMC12737096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.