Evidence map›Paper›PMID 41471623›Full record

ArticleSensors (Basel, Switzerland)2025

Towards Heart Rate Estimation in Complex Multi-Target Scenarios: A High-Precision FMCW Radar Scheme Integrating HDBS and VLW.

Xuefei Dong, Yunxue Liu, Jinwei Wang, Shie Wu, Chengyou Wang, Shiqing Tang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xuefei DongSchool of Physics and Electronic Information, Yantai University, Yantai 264005, China.ORCID 0009-0003-0694-3392
Yunxue LiuSchool of Physics and Electronic Information, Yantai University, Yantai 264005, China.ORCID 0009-0003-4564-3237
Jinwei WangSchool of Physics and Electronic Information, Yantai University, Yantai 264005, China.ORCID 0009-0008-4826-4757
Shie WuSchool of Physics and Electronic Information, Yantai University, Yantai 264005, China.ORCID 0000-0001-8264-0682
Chengyou WangSchool of Airspace Science and Engineering, Shandong University, Weihai 264209, China.ORCID 0000-0002-0901-2492
Shiqing TangSchool of Physics and Electronic Information, Yantai University, Yantai 264005, China.ORCID 0009-0001-8054-001X

Funding

Chinese National Natural Science Foundation 62201491
6 · The paper itself

Abstract

Non-contact heart rate estimation technology based on frequency-modulated continuous wave (FMCW) radar has garnered extensive attention in single-target scenarios, yet it remains underexplored in multi-target environments. Accurate discrimination of multiple targets and precise estimation of their heart rates constitute key challenges in the multi-target domain. To address these issues, we propose a novel scheme for multi-target heart rate estimation. First, a high-precision distance-bin selection (HDBS) method is proposed for target localization in the range domain. Next, multiple-input multiple-output (MIMO) array processing is combined with the Root-multiple signal classification (Root-MUSIC) algorithm for angular domain estimation, enabling accurate discrimination of multiple targets. Subsequently, we propose an efficient method for interference suppression and vital sign extraction that cascades variational mode decomposition (VMD), local mean decomposition (LMD), and wavelet thresholding (WT) termed as VLW, which enables high-quality heartbeat signal extraction. Finally, to achieve high-precision and super-resolution heart rate estimation with low computational burden, an improved fast iterative interpolated beamforming (FIIB) algorithm is proposed. Specifically, by leveraging the conjugate symmetry of real-valued signals, the improved FIIB algorithm reduces the execution time by approximately 60% compared to the standard version. In addition, the proposed scheme provides sufficient signal-to-noise ratio (SNR) gain through low-complexity accumulation in both distance and angle estimation. Six experimental scenarios are designed, incorporating densely arranged targets and front-back occlusion, and extensive experiments are conducted. Results show this scheme effectively discriminates multiple targets in all tested scenarios with a mean absolute error (MAE) below 2.6 beats per minute (bpm), demonstrating its viability as a robust multi-target heart rate estimation scheme in various engineering fields.

Indexed as

fast iterative interpolation beamforming (FIIB)frequency-modulated continuous wave (FMCW)multiple-input multiple-output (MIMO)multi-targetvital sign monitoring

Identifiers

PMID41471623
PMCPMC12737220

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.