ArticleSensors (Basel, Switzerland)2025
Study on an All-Optic Temperature Sensor Based on a Low-Coherent Optical Interferometry.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Optical temperature sensors with intrinsic characteristics of explosion-proof are particularly suitable for the petrochemical industry, etc. However, their applications remain limited by environmental compatibility, etc. Here, we developed an all-optic temperature sensor using an anti-bending single-mode optical fiber in a 3.5 m length and a 0.25 mm outer diameter to match a stainless tube with a 0.4 mm inner diameter. The fiber was threaded into the tube, well bonded with epoxy at both ends of the tube, and configured as one arm of a low-coherent Michelson interferometer. Then, the tube with an embedded sensing fiber was fabricated into a spring, whose final length was about 70 mm with an outside diameter of 13 mm. Changes in temperature alter the lengths of the stainless tube spring in a thermoelastic way, thereby modifying the inner fiber length and producing an optical path difference between the sensing fiber and the packaged reference arm of the interferometer. A temperature calibration was carried out from -25 to 65 °C, and the results demonstrated that the hysteresis of the spring sensor was within ±1.16 °C and the sensitivity was 0.34 °C, which was verified by using a platinum resistance temperature sensor (PT-100). This work provides a reference for further intrinsic optical temperature sensor design.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.