Evidence map›Paper›PMID 41470251›Full record

ArticleMaterials (Basel, Switzerland)2025

Comparative Study on the Wear Resistance of C&B-Type Polymer Materials for Temporary Crowns Manufactured Using 3D DLP Printing Technology.

Marcel Firlej, Daniel Pieniak, Andrzej Snarski-Adamski, Barbara Biedziak, Agata Niewczas, Jana Petru, Jonas Matijošius, Zbigniew Krzysiak, Katarzyna Zaborowicz

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Marcel FirlejDepartment of Craniofacial Anomalies, Poznan University of Medical Sciences, Bukowska 70, 60-812 Poznan, Poland.ORCID 0000-0002-4680-0770
Daniel PieniakTribology Center, Łukasiewicz Research Network-Institute for Sustainable Technologies (L-ITEE), Pułaskiego 6/10, 26-600 Radom, Poland.ORCID 0000-0001-7807-3515
Andrzej Snarski-AdamskiTribology Center, Łukasiewicz Research Network-Institute for Sustainable Technologies (L-ITEE), Pułaskiego 6/10, 26-600 Radom, Poland.ORCID 0000-0002-4962-192X
Barbara BiedziakDepartment of Craniofacial Anomalies, Poznan University of Medical Sciences, Bukowska 70, 60-812 Poznan, Poland.ORCID 0000-0002-6150-9957
Agata NiewczasDepartment of Conservative Dentistry with Endodontics, Medical University of Lublin, W. Chodźki 6, 20-093 Lublin, Poland.ORCID 0000-0002-8003-5638
Jana PetruFaculty of Mechanical Engineering, VSB-Technical University of Ostrava, Poruba, 70800 Ostrava, Czech Republic.ORCID 0000-0002-2378-5678
Jonas MatijošiusMechanical Science Institute, Vilnius Gediminas Technical University, Plytinės Str. 25, 10105 Vilnius, Lithuania.ORCID 0000-0001-6006-9470
Zbigniew KrzysiakDepartment of Mechanical Engineering and Automation, Faculty of Production Engineering, University of Life Sciences in Lublin, Głęboka 28, 20-612 Lublin, Poland.ORCID 0000-0002-4950-7481
Katarzyna ZaborowiczDepartment of Craniofacial Anomalies, Poznan University of Medical Sciences, Bukowska 70, 60-812 Poznan, Poland.ORCID 0000-0003-0337-6110

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

DLP (Digital Light Processing) 3D printing enables precise fabrication of temporary crowns. Tribological properties of these materials affect clinical durability, wear resistance, and masticatory function. This study compared three C&B-type photopolymers for DLP-printed temporary crowns: Gr-17.1 temporary It, Gr-17 temporary (Pro3dure), and VarseoSmile Temp (BEGO). Samples were printed, post-processed, and polished. Surface topography (Sa, Sz) was measured via white light interferometry, and scratch resistance was evaluated with a Rockwell indenter. Sliding wear tests under wet conditions (37 °C, 90% RH) were conducted using an SRV 4 tester at 25 N for 20,000 cycles. VarseoSmile Temp showed the highest scratch and sliding wear resistance, with the lowest mean volumetric wear (0.025 mm

Indexed as

dental polymersDLP 3D printingfiller contentscratch resistancetemporary crownswear resistance

Identifiers

PMID41470251
PMCPMC12735166

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.