Evidence map›Paper›PMID 41469899›Full record

ArticleEar and hearing

The Relationships Between Cochlear Nerve Health and AzBio Sentence Scores in Quiet and Noise in Postlingually Deafened Adult Cochlear Implant Users.

Zi Gao, Yi Yuan, Jacob J Oleson, Christopher R Mueller, Ian C Bruce, René H Gifford, Shuman He

Abstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Zi GaoDepartment of Otolaryngology - Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA.
Yi YuanDepartment of Audiology, San José State University, San José, California, USA.
Jacob J OlesonDepartment of Biostatistics, The University of Iowa, Iowa City, Iowa, USA.
Christopher R MuellerDepartment of Otolaryngology - Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA.
Ian C BruceDepartment of Electrical and Computer Engineering, McMaster University, Hamilton, Ontario, Canada.
René H GiffordDepartment of Hearing and Speech Sciences, Vanderbilt School of Medicine, Nashville, Tennessee, USA.
Shuman HeDepartment of Otolaryngology - Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA.

Funding

NEURAL ENCODING AND AUDITORY PERCEPTION IN COCHLEAR IMPLANT USERSR01DC016038 · NIDCD · OHIO STATE UNIVERSITY · PI HE, SHUMAN · 2017 to 2021
$2.3M
AUDITORY NEURAL FUNCTION IN IMPLANTED PATIENTS WITH USHER SYNDROMER21DC019458 · NIDCD · OHIO STATE UNIVERSITY · PI HE, SHUMAN · 2021 to 2022
$433k
NIDCD NIH HHS 1R01 DC016038NIDCD NIH HHS R01 DC016038NIDCD NIH HHS R21 DC019458
6 · The paper itself

Abstract

objectivesThis study investigated the relationships between the cochlear nerve (CN) health and sentence-level speech perception outcomes measured in quiet and noise in postlingually deafened adult cochlear implant (CI) users.

designStudy participants included 28 postlingually deafened adult CI users with a Cochlear Nucleus device. For each participant, only one ear was tested. Neural health of the CN was assessed at three or four electrode locations across the electrode array using two parameters derived from results of the electrically evoked compound action potential (eCAP). One parameter was the phase locking value (PLV), which estimated neural synchrony in the CN. The other parameter was the sensitivity of the eCAP amplitude growth function (AGF) slope to changes in the interphase gap (IPG) of biphasic electrical pulses (i.e., the IPGE slope ). Speech perception was tested using AzBio sentences in both quiet and a 10-talker babble background noise with +5 dB and +10 dB signal to noise ratios (SNR). IPGE slope and PLV values were averaged across electrodes for each subject, both with and without weighting by the frequency importance function (FIF) of the AzBio sentences. Pearson and Spearman correlations were used to assess the pairwise relationships between the IPGE slope , the PLV, and age. Multiple linear regression models with AzBio score as the outcome and the PLV and the IPGE slope as predictors were used to evaluate the associations between the three variables while controlling for age.

resultsThe IPGE slope and the PLV demonstrated different patterns with regard to their relationships with electrode location, age, and speech perception. The PLV, but not the IPGE slope , differed significantly across electrodes, where the apical electrodes had larger PLVs (better neural synchrony) than the basal electrodes. The IPGE slope , but not the PLV, was significantly correlated with participant's age, where smaller IPGE slope values (poorer spiral ganglion neuron density) were associated with more advanced age. After controlling for the effect of age, the PLV, but not the IPGE slope , was significantly associated with AzBio scores in the +5 dB SNR condition, where larger PLVs predicted better speech perception. Neither the PLV nor the IPGE slope was significantly associated with AzBio score in quiet or in the +10 dB SNR condition. The result patterns remained the same regardless of whether the mean values of the IPGE slope and the PLV were weighted by the AzBio FIF. The result patterns generally did not change with fitting methods or input/output scales of the AGF slopes.

conclusionsThe IPGE slope and the PLV quantify different aspects of CN health. The positive association between the PLV and AzBio scores in the +5 dB SNR condition suggests that neural synchrony is important for speech perception in adult CI users in challenging listening conditions with a relatively high noise level. The lack of association between age and the PLV indicates that reduced neural synchrony in the CN might not be the primary factor accounting for the greater deficits in understanding speech in noise observed in older CI users, as compared with middle-aged CI users.

Indexed as

Cochlear ImplantsCochlear NerveDeafnessSpeech PerceptionAdultAgedAged, 80 and overCochlear ImplantationFemaleHumansMaleMiddle AgedNoiseCochlear implantsCochlear nerveNeural healthNeural synchronySpeech perception

Identifiers

PMID41469899
PMCPMC13397381

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.