Evidence map›Paper›PMID 41467031›Full record

ArticleClinical, cosmetic and investigational dentistry2025

Custom Sleeve Parameters in Static Guided Endodontic Access: Influence on Deviation Control in Pulp Canal Obliteration.

Anna Muryani, Dudi Aripin, Hendra Dian Adhita Dharsono, Satrio Wicaksono, Zainul Ahmad Rajion, Wandi Prasetia

Abstract read
In one paragraph

Article in Clinical, cosmetic and investigational dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Anna MuryaniDoctoral Programme Faculty of Medicine, Universitas Padjadjaran, Bandung, West Java, Indonesia.ORCID 0000-0003-2228-5433
Dudi AripinConservative Dentistry Department Faculty of Dentistry, Universitas Padjadjaran, Bandung, West Java, Indonesia.
Hendra Dian Adhita DharsonoConservative Dentistry Department Faculty of Dentistry, Universitas Padjadjaran, Bandung, West Java, Indonesia.ORCID 0000-0003-4365-9254
Satrio WicaksonoFaculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, West Java, Indonesia.ORCID 0000-0002-1340-7630
Zainul Ahmad RajionDepartment Oral Maxillofacial Surgery and Oral Diagnosis Kulliyyah of Dentistry International Islamic University Malaysia, Kuantan, Malaysia.
Wandi PrasetiaFaculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, West Java, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Pulp canal obliteration (PCO) narrows the root canal, complicating access and increasing treatment risks. This study aims to evaluate the accuracy of static guided endodontic access (SGEA) using custom sleeves of different materials and heights compared to conventional freehand access (FHA) in pulp canal obliteration. Methods: An in vitro experimental study was conducted using 48 resin maxillary incisors modeled to simulate pulp canal obliteration via CBCT, intraoral scanner, and 3D printing. The samples were divided into eight groups (n=6): a negative control (freehand access-FHA), a positive control (Titanium Steco 5 mm sleeve), and six static guided endodontic access (SGEA) groups using custom inner sleeves made of Chrome-Cobalt (CoCr) and Zirconia at three heights (3 mm, 5 mm, and 7 mm). Coronal and sagittal deviations between pre- and postoperative CBCT scans were analyzed using one-way ANOVA and Bonferroni post hoc tests (α=0.05). Results: All SGEA groups demonstrated significantly lower deviation values compared to freehand access (p < 0.05). The mean coronal deviation ranged from 1.83° to 6.90°, with the lowest value observed in the Zirconia 7 mm sleeve group (1.83°±1.84°). Sagittal deviation ranged from 2.48° to 30.08°, also lowest in the Zirconia 7 mm group (2.48°±2.43°) and highest in the freehand access group (30.08°±5.93°). Increased sleeve height improved angular precision, and zirconia demonstrated superior dimensional stability compared to chrome-cobalt and titanium. Conclusion: The SGEA technique provided higher accuracy than freehand access in controlling drilling deviation. Among the tested parameters, the custom 3D-printed zirconia sleeve with a 7 mm height yielded the best precision, supporting its potential use in minimizing iatrogenic risk during endodontic access of obliterated canals. This in vitro study on resin models requires further in vivo validation for clinical application.

Indexed as

3D printingcustom sleeve designdeviation controlguided endodonticsminimally invasive endodonticspulp canal obliteration

Identifiers

PMID41467031
PMCPMC12744872

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.